Duplex ultrasound evaluation for dialysis access selection and maintenance: a practical guide
- PMID: 18379973
Duplex ultrasound evaluation for dialysis access selection and maintenance: a practical guide
Abstract
Detailed case directed history and examination is the mainstay of dialysis access modality selection, ie site and type of access, as well as for maintenance of dialysis access for longevity. As a logical step following history and physical examination, duplex ultrasound evaluation (DUE) is the most cost effective and non-invasive screening tool for evaluation for access placement and for assessment of an established access. Pre-operative vascular mapping allows selection of the optimal dialysis access modality and site. In established accesses, duplex ultrasound testing will diagnose the majority of vascular access complications and direct proper surgical or interventional radiology management. This review outlines a practical decision-making algorithm using DUE for choosing and managing the dialysis access.
Similar articles
-
Preoperative radiological assessment for vascular access.Eur J Vasc Endovasc Surg. 2006 Jan;31(1):64-9. doi: 10.1016/j.ejvs.2005.10.002. Eur J Vasc Endovasc Surg. 2006. PMID: 16338204 Review.
-
Estimation of brachial artery volume flow by duplex ultrasound imaging predicts dialysis access maturation.J Vasc Surg. 2015 Jun;61(6):1521-7. doi: 10.1016/j.jvs.2015.01.036. Epub 2015 Mar 11. J Vasc Surg. 2015. PMID: 25769390
-
Interpretation of duplex ultrasound dialysis access testing.Semin Vasc Surg. 2013 Jun-Sep;26(2-3):120-6. doi: 10.1053/j.semvascsurg.2013.12.001. Epub 2013 Dec 4. Semin Vasc Surg. 2013. PMID: 24636609 Review.
-
Outcome after autogenous brachial-basilic upper arm transpositions in the post-National Kidney Foundation Dialysis Outcomes Quality Initiative era.J Vasc Surg. 2005 Nov;42(5):951-6. doi: 10.1016/j.jvs.2005.07.042. J Vasc Surg. 2005. PMID: 16275453
-
Outcome after autogenous brachial-axillary translocated superficial femoropopliteal vein hemodialysis access.J Vasc Surg. 2004 Aug;40(2):311-8. doi: 10.1016/j.jvs.2004.04.018. J Vasc Surg. 2004. PMID: 15297827
Cited by
-
Color Doppler ultrasound and arteriovenous fistulas for hemodialysis.J Ultrasound. 2014 Jul 11;17(4):253-63. doi: 10.1007/s40477-014-0113-6. eCollection 2014 Dec. J Ultrasound. 2014. PMID: 25368682 Free PMC article. Review.
-
Multiparametric ultrasound for upper extremity dialysis access evaluation.Ultrasonography. 2023 Oct;42(4):490-507. doi: 10.14366/usg.23064. Epub 2023 Jul 12. Ultrasonography. 2023. PMID: 37723649 Free PMC article.
-
Improved Ultrasound-Guided Balloon-Assisted Maturation Angioplasty Using Drug-Eluting Balloons in the First Autogenous Arteriovenous Fistula Procedure: Early Experience.Biomedicines. 2024 May 2;12(5):1005. doi: 10.3390/biomedicines12051005. Biomedicines. 2024. PMID: 38790967 Free PMC article.
-
Dialysis access in europe and north america: are we on the same path?Semin Intervent Radiol. 2009 Jun;26(2):96-105. doi: 10.1055/s-0029-1222452. Semin Intervent Radiol. 2009. PMID: 21326499 Free PMC article.
-
Evaluation of Diagnostic Values of Clinical Assessment in Determining the Maturation of Arteriovenous Fistulas for Satisfactory Hemodialysis.Adv Biomed Res. 2017 Mar 1;6:18. doi: 10.4103/2277-9175.201330. eCollection 2017. Adv Biomed Res. 2017. PMID: 28349021 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical