Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 May 15;80(10):3811-7.
doi: 10.1021/ac800054t. Epub 2008 Apr 2.

Differentiation and identification of recombinant human erythropoietin and darbepoetin Alfa in equine plasma by LC-MS/MS for doping control

Affiliations

Differentiation and identification of recombinant human erythropoietin and darbepoetin Alfa in equine plasma by LC-MS/MS for doping control

Fuyu Guan et al. Anal Chem. .

Abstract

Recombinant human erythropoietin (rhEPO) and darbepoetin alfa (DPO) are protein-based drugs for the treatment of anemia in humans by stimulating erythrocyte production. However, these agents are abused in human and equine sports due to their potential to enhance performance. This paper describes the first method for differentiation and identification of rhEPO and DPO in equine plasma by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The method comprised analyte extraction and enrichment by immunoaffinity separation with anti-rhEPO antibodies, dual digestion by trypsin and peptide-N-glycosidase F (PNGase F), and analysis by LC-MS/MS. Two unique deglycosylated tryptic peptides, (21)EAENITTGCAEHCSLNENITVPDTK (45) (T 5) from rhEPO and (77)GQALLVNSSQVNETLQLHVDK (97) (T 9) from DPO, were employed for differentiation and identification of rhEPO and DPO via LC retention times and major product ions. The limit of identification was 0.1 ng/mL for DPO and 0.2 ng/mL for rhEPO in equine plasma, and the limit of detection was 0.05 ng/mL for DPO and 0.1 ng/mL for rhEPO. Analyte carryover problem encountered was solved by adding 20% acetonitrile to the solvent of the sample digest to increase solubility of the peptides. This method was successfully applied to identification of DPO in plasma samples collected from a research horse following DPO administration and from racehorses out of competition in North America. Thus, it provides a powerful tool in the fight against blood doping with rhEPO and DPO in the horse racing industry.

PubMed Disclaimer

Publication types

LinkOut - more resources