Abstract
Background: Vena contracta width (VCW) as an estimate of effective regurgitant orifice area (EROA) is an accepted parameter of mitral regurgitation (MR) severity. However, uncertainty exists in cases in which VCW at the same time appears narrow in 4-chamber (4CH) view and broad in 2-chamber (2CH) view as common in functional MR with noncircular or slit-like regurgitant orifices. We therefore hypothesized that new real-time 3-dimensional color Doppler echocardiography (RT3DE) can be used for direct assessment of the size and shape of vena contracta area (VCA) in an en face view and to determine the potential error of conventional VCW measurement on estimation of EROA.
Methods: RT3DE was performed in 57 patients with relevant MR of different etiologies. Manual tracing of VCA in a cross-sectional plane through the vena contracta was compared with VCW in 4CH and 2CH views. As a comparative approach to VCA-3D, EROA was calculated using the hemispheric and hemielliptic proximal isovelocity surface (PISA) area method.
Results: Direct measurement of VCA-3D was feasible in all patients within 2.6 +/- 0.7 minutes. RT3DE revealed significant asymmetry of VCA in functional compared with organic MR (P < .001). Among all patients, VCW-4CH and VCW-2CH correlated only moderately to VCA-3D (r =.77; r =.80). Mean VCW correlated and agreed best with VCA-3D (r =.90). VCA-3D correlated and agreed well with EROA by hemielliptic PISA (r = .96, mean error: -0.09 +/- 0.14 cm(2)) compared with significant underestimation of hemispheric PISA in noncircular lesions.
Conclusions: Direct assessment of VCA using RT3DE revealed significant asymmetry of VCA in functional MR compared with organic MR, resulting in poor estimation of EROA by single VCW measurements.
Similar articles
-
Quantification of mitral valve regurgitation: new solutions provided by 3D echocardiography.Curr Cardiol Rep. 2013 Aug;15(8):384. doi: 10.1007/s11886-013-0384-0. Curr Cardiol Rep. 2013. PMID: 23812836 Review.
-
Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta.J Am Soc Echocardiogr. 2008 Dec;21(12):1337-46. doi: 10.1016/j.echo.2008.09.022. J Am Soc Echocardiogr. 2008. PMID: 19041578
-
Real-Time 3-Dimensional Echocardiographic Assessment of Effective Regurgitant Orifice Area in Dogs With Myxomatous Mitral Valve Disease.J Vet Intern Med. 2017 Mar;31(2):303-310. doi: 10.1111/jvim.14642. Epub 2017 Jan 21. J Vet Intern Med. 2017. PMID: 28109120 Free PMC article.
-
Three-dimensional versus two-dimensional echocardiographic assessment of functional mitral regurgitation proximal isovelocity surface area.Anesth Analg. 2015 Mar;120(3):534-542. doi: 10.1213/ANE.0000000000000409. Anesth Analg. 2015. PMID: 25166465
-
Real-Time Three-Dimensional Echocardiographic Assessment of Severity of Mitral Regurgitation Using Proximal Isovelocity Surface Area and Vena Contracta Area Method. Lessons We Learned and Clinical Implications.Curr Cardiovasc Imaging Rep. 2015;8(10):38. doi: 10.1007/s12410-015-9356-7. Curr Cardiovasc Imaging Rep. 2015. PMID: 26322152 Free PMC article. Review.
Cited by
-
Intraoperative comparison of 2D versus 3D transesophageal echocardiography for quantitative assessment of mitral regurgitation.Ann Card Anaesth. 2021 Apr-Jun;24(2):163-171. doi: 10.4103/aca.ACA_28_20. Ann Card Anaesth. 2021. PMID: 33884971 Free PMC article.
-
Quantification of mitral valve regurgitation: new solutions provided by 3D echocardiography.Curr Cardiol Rep. 2013 Aug;15(8):384. doi: 10.1007/s11886-013-0384-0. Curr Cardiol Rep. 2013. PMID: 23812836 Review.
-
Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve.Curr Cardiol Rep. 2014 Jan;16(1):439. doi: 10.1007/s11886-013-0439-2. Curr Cardiol Rep. 2014. PMID: 24292888 Review.
-
[Structure and function of the mitral valve. Eligibility criteria for surgical and interventional approaches].Herz. 2015 Jun;40(4):569-75. doi: 10.1007/s00059-015-4234-2. Herz. 2015. PMID: 25963035 Review. German.
-
The value of three-dimensional color Doppler trans-esophageal echocardiography in predicting the number of MitraClip devices needed during the procedure.Egypt Heart J. 2017 Dec;69(4):247-251. doi: 10.1016/j.ehj.2017.03.004. Epub 2017 Apr 7. Egypt Heart J. 2017. PMID: 29622985 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials