Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Aug;21(8):941-7.
doi: 10.1016/j.echo.2008.02.004. Epub 2008 Apr 2.

Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography

Affiliations
Comparative Study

Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography

Piotr Lipiec et al. J Am Soc Echocardiogr. 2008 Aug.

Abstract

Objective: The aims of this prospective study were to compare the diagnostic value of accelerated vasodilator stress real-time myocardial contrast echocardiography (MCE) and single photon emission computed tomography (SPECT) against coronary angiography and to evaluate whether the addition of MCE perfusion data improves the diagnostic accuracy of stress echocardiography.

Methods: A total of 103 patients with suspected or known stable coronary artery disease (CAD) underwent SPECT and accelerated high-dose dipyridamole (0.84 mg/kg intravenously for 4 minutes) atropine (up to 1 mg intravenously) stress real-time qualitative MCE. The presence of CAD was detected by coronary angiography.

Results: CAD defined as >or= 70% stenosis was detected in 77% of patients, whereas 86% of patients had CAD defined as >or= 50% stenosis. In a territory-by-territory analysis, the concordance between MCE and SPECT in detecting perfusion defects varied from 72.8% (kappa = 0.386) to 89.3% (kappa = 0.642). There were no significant differences between MCE and SPECT in sensitivity, specificity, and diagnostic accuracy for identifying patients with CAD. Combining MCE and wall motion abnormality analysis significantly improved the sensitivity of the test compared with wall motion abnormality analysis alone.

Conclusions: Accelerated vasodilator stress real-time MCE yields a good concordance with SPECT in detection of perfusion defects and a similar diagnostic value for the detection of CAD. The addition of MCE perfusion data improves the diagnostic value of stress echocardiography.

PubMed Disclaimer

Publication types