Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jun;29(6):1067-70.
doi: 10.3174/ajnr.A1046. Epub 2008 Apr 3.

Interval change in size of venous pouch canine bifurcation aneurysms over a 10-month period

Affiliations

Interval change in size of venous pouch canine bifurcation aneurysms over a 10-month period

T Tsumoto et al. AJNR Am J Neuroradiol. 2008 Jun.

Abstract

Background and purpose: The natural history study of experimental aneurysms is important for the evaluation of new endovascular occlusion devices. Our purpose was to evaluate the natural history of experimental venous pouch bifurcation aneurysms in mongrel dogs up to a 10-month period.

Materials and methods: Serial digital subtraction angiography was performed in 5 bifurcation aneurysms 1, 4, 7, and 10 months after surgical creation. Aneurysm dimensions, including height, width, and neck diameter, and animal body weights were measured. Comparisons of each parameter were performed using the Friedman test and the paired Wilcoxon signed-rank test.

Results: Four of 5 aneurysms were patent during a 10-month follow-up period. One aneurysm was regarded as a partially thrombosed aneurysm at 1 month, though the extent of partial thrombosis lessened at 10 months. Bifurcation aneurysms progressively increased in size (aneurysm height, width, and neck diameter) during the first several months.

Conclusion: If this experimental model is used to evaluate new endovascular devices for cerebral aneurysm treatment, investigators should be aware of early progressive aneurysm enlargement.

PubMed Disclaimer

Figures

Fig 1.
Fig 1.
Representative DSA 1 (A), 4 (B), 7 (C), and 10 (D) months after creation. The venous pouch bifurcation aneurysms progressively increase in size during the first several months before appearing to stabilize.
Fig 2.
Fig 2.
Representative DSA 1 (A), 4 (B), 7 (C), and 10 (D) months after creation. The extent of partial thrombosis is less at 10 months than at the time of aneurysm creation.
Fig 3.
Fig 3.
Bar graphs illustrate mean sizes of height (A), width (B), neck diameter (C), and body weight (D) in each group.

Similar articles

Cited by

References

    1. Kallmes DF, Fujiwara NH. New expandable hydrogel-platinum coil hybrid device for aneurysm embolization. AJNR Am J Neuroradiol 2002;23:1580–88 - PMC - PubMed
    1. Murayama Y, Suzuki Y, Vinuela F, et al. Development of a biologically active Guglielmi detachable coil for the treatment of cerebral aneurysms: part I-In vitro study. AJNR Am J Neuroradiol 1999;20:1986–91 - PMC - PubMed
    1. Murayama Y, Vinuela F, Suzuki Y, et al. Development of the biologically active Guglielmi detachable coil for the treatment of cerebral aneurysms: part II-An experimental study in a swine aneurysm model. AJNR Am J Neuroradiol 1999;20:1992–99 - PMC - PubMed
    1. Murayama Y, Vinuela F, Tateshima S, et al. Bioabsorbable polymeric material coils for embolization of intracranial aneurysm: a preliminary experimental study. J Neurosurg 2001;94:454–63 - PubMed
    1. Tsumoto T, Matsumoto H, Terada T, et al. A polyvinyl alcohol core coil containing basic fibroblast growth factor evaluated in rabbits with aneurysms induced by elastase. Neurosurgery 2007;61:160–66 - PubMed