Extended spectrum Beta-Lactamase-producing Klebsiella pneumoniae septicaemia outbreak in the Neonatal Intensive Care Unit of a tertiary hospital in Nigeria
- PMID: 18390061
Extended spectrum Beta-Lactamase-producing Klebsiella pneumoniae septicaemia outbreak in the Neonatal Intensive Care Unit of a tertiary hospital in Nigeria
Abstract
Between March and August 2002 a cluster of nosocomial septicaemia associated with Extended Spectrum beta lactamase (ESBL)-producing Klebsiella pneumoniae was observed in 11 neonates from the neonatal intensive care unit of a 200-bed tertiary hospital in Abuja, the Federal Capital territory of Nigeria. An investigation was conducted to identify the possible reservoirs and mode of transmission. Infection control measures and epidemiologic surveillance were executed. The environment was investigated by collecting and processing several swab samples for microbiological studies. Antibiogram tests and extended spectrum beta lactamase production test were performed on all K. pneumoniae isolates from both the environment and the patients, and all bacteraemic and environmental isolates of K. pneumoniae compared. A total of 30 K. pneumoniae isolates made up of 17 from the patients and 13 from the environment were analysed. An identical antibiogram was found in 24 isolates, which included all the 17 from the patients and the 7 from the hands of staff, sink and incubator surface in the NICU. Mortality rate from the outbreak was 36.4% and constituted 10.8% of all deaths in the unit in 2002. Overall mortality in the unit for 2002 was 28.9%. The outbreak significantly caused more deaths than usual in the unit. The nosocomial septicaemia was caused by a single ESBL-producing strain of K. pneumnoniae brought into the hospital by a neonate delivered and admitted from an external health institution. Sink and the incubator were also contaminated by the same strain.
Similar articles
-
Nosocomial outbreak of septicaemia in neonatal intensive care unit due to extended spectrum β-lactamase producing Klebsiella pneumoniae showing multiple mechanisms of drug resistance.Indian J Med Microbiol. 2010 Oct-Dec;28(4):380-4. doi: 10.4103/0255-0857.71834. Indian J Med Microbiol. 2010. PMID: 20966575
-
Prompt control of an outbreak caused by extended-spectrum β-lactamase-producing Klebsiella pneumoniae in a neonatal intensive care unit.J Pediatr. 2013 Sep;163(3):672-9.e1-3. doi: 10.1016/j.jpeds.2013.03.001. Epub 2013 Apr 10. J Pediatr. 2013. PMID: 23582136
-
[Molecular characterization of an outbreak caused by CTX-M-12-producing Klebsiella pneumoniae in a Colombian hospital's neonatal intensive care unit].Biomedica. 2006 Sep;26(3):408-14. Biomedica. 2006. PMID: 17176004 Spanish.
-
Microbiologic spectrum and susceptibility pattern of clinical isolates from the pediatric intensive care unit in a single medical center - 6 years' experience.J Microbiol Immunol Infect. 2009 Apr;42(2):160-5. J Microbiol Immunol Infect. 2009. PMID: 19597649 Review.
-
Hospital-acquired infections in the neonatal intensive care unit--Klebsiella pneumoniae.Semin Perinatol. 2002 Oct;26(5):340-5. doi: 10.1053/sper.2002.36267. Semin Perinatol. 2002. PMID: 12452506 Review.
Cited by
-
Molecular detection and antibiotic resistance pattern of extended-spectrum beta-lactamase producing Escherichia coli in a Tertiary Hospital in Enugu, Nigeria.Ann Clin Microbiol Antimicrob. 2019 Dec 12;18(1):41. doi: 10.1186/s12941-019-0342-9. Ann Clin Microbiol Antimicrob. 2019. PMID: 31831001 Free PMC article.
-
Preventing the spread of multidrug-resistant gram-negative pathogens: recommendations of an expert panel of the German Society For Hygiene and Microbiology.Dtsch Arztebl Int. 2012 Jan;109(3):39-45. doi: 10.3238/arztebl.2012.0039. Epub 2012 Jan 20. Dtsch Arztebl Int. 2012. PMID: 22334820 Free PMC article. Review.
-
The definition of pneumonia, the assessment of severity, and clinical standardization in the Pneumonia Etiology Research for Child Health study.Clin Infect Dis. 2012 Apr;54 Suppl 2(Suppl 2):S109-16. doi: 10.1093/cid/cir1065. Clin Infect Dis. 2012. PMID: 22403224 Free PMC article. Review.
-
Safety and effectiveness of a non-electric infant warmer for hypothermia in Rwanda: A cluster-randomized stepped-wedge trial.EClinicalMedicine. 2021 Apr 16;34:100842. doi: 10.1016/j.eclinm.2021.100842. eCollection 2021 Apr. EClinicalMedicine. 2021. PMID: 33997734 Free PMC article.
-
Risk and causes of paediatric hospital-acquired bacteraemia in Kilifi District Hospital, Kenya: a prospective cohort study.Lancet. 2011 Dec 10;378(9808):2021-2027. doi: 10.1016/S0140-6736(11)61622-X. Epub 2011 Nov 29. Lancet. 2011. PMID: 22133536 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Medical