. 2008 Sep;18(9):1809-17.
doi: 10.1007/s00330-008-0966-1. Epub 2008 Apr 8.

Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose

Affiliations

Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose

Sebastian Leschka et al. Eur Radiol. 2008 Sep.

Abstract

The purpose of this study was to investigate the effect of low kilovoltage dual-source computed tomography coronary angiography (CTCA) on qualitative and quantitative image quality parameters and radiation dose. Dual-source CTCA with retrospective ECG gating was performed in 80 consecutive patients of normal weight. Forty were examined with a standard protocol (120 kV/330mAs), 20 were examined at 100 kV/330mAs, and 20 at 100 kV/220mAs. Two blinded observers independently assessed image quality of each coronary segment and measured the image parameters noise, attenuation, and contrast-to-noise ratio (CNR). The effective radiation dose was calculated using CT dose volume index and the dose-length product. Diagnostic image quality was obtained in 99% of all coronary segments (1,127/1,140) without significant differences among the protocols. Image noise, attenuation, and CNR were significantly higher for 100 kV/330mAs (26 +/- 3 HU, 549 +/- 62 HU, 25.5 +/- 3.2; each P < 0.01) and 100 kV/220mAs (27 +/- 2 HU, 560 +/- 43 HU, 25.0 +/- 2.2; each P < 0.01) when compared to the 120-kV protocol (21 +/- 2 HU, 317 +/- 28 HU, 20.6 +/- 1.7). There was no significant difference between the two 100-kV protocols. Estimated effective radiation dose of the 120-kV protocol (8.9 +/- 1.2 mSv) was significantly higher than the 100 kV/330mAs (6.7 +/- 0.8 mSv, P < 0.01) or 100 kV/220mAs (4.4 +/- 0.6 mSv, P < 0.001) protocols. Dual-source CTCA with 100 kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dose.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eur Heart J. 2005 Aug;26(15):1482-7 - PubMed
    1. AJR Am J Roentgenol. 2006 Jun;186(6 Suppl 2):S387-90 - PubMed
    1. Eur Radiol. 2008 Mar;18(3):592-9 - PubMed
    1. Eur J Radiol. 2006 Mar;57(3):373-9 - PubMed
    1. Radiology. 2007 Jun;243(3):775-84 - PubMed

Publication types