Ion yield improvement for static secondary ion mass spectrometry by use of polyatomic primary ions
- PMID: 18401858
- DOI: 10.1002/rcm.3533
Ion yield improvement for static secondary ion mass spectrometry by use of polyatomic primary ions
Abstract
Static secondary ion mass spectrometry (S-SIMS) is one of the potentially most powerful and versatile tools for the analysis of surface components at the monolayer level. Current improvements in detection limit (LOD) and molecular specificity rely on the optimisation of the desorption-ionisation (DI) process. As an alternative to monoatomic projectiles, polyatomic primary ion (P.I.) bombardment increases ion yields non-linearly. Common P.I. sources are Ga+ (liquid metal ion gun (LMIG), SF5+ (electron ionisation) and the newer Au(n)+, Bi(n)q+ (both LMIG) and C60+ (electron ionisation) sources. In this study the ion yield improvement obtained by using the newly developed ion sources is assessed. Two dyes (zwitterionic and/or thermolabile polar functionalities on a largely conjugated backbone) were analysed as a thin layer using Ga+, SF5+, C60+, Bi+, Bi3(2+) and Bi5(2+) projectiles under static conditions. The study aims at evaluating the improvement in LOD, useful and characteristic yield and molecular specificity. The corrected total ion count values for the different P.I. sources are compared for different instruments to obtain a rough estimate of the improvements. Furthermore, tentative ionisation and fragmentation schemes are provided to describe the generation of radical and adduct ions. Characteristic ion yields are discussed for the different P.I. sources. An overview of the general appearances of the mass spectra obtained with the different P.I. sources is given to stress the major improvement provided by polyatomic P.I.s in yielding information at higher m/z values.
Similar articles
-
Use of monoatomic and polyatomic projectiles for the characterisation of polylactic acid by static secondary ion mass spectrometry.Rapid Commun Mass Spectrom. 2005;19(18):2517-27. doi: 10.1002/rcm.2089. Rapid Commun Mass Spectrom. 2005. PMID: 16106345
-
Effects of metal nanoparticles on the secondary ion yields of a model alkane molecule upon atomic and polyatomic projectiles in secondary ion mass spectrometry.Anal Chem. 2008 Aug 15;80(16):6235-44. doi: 10.1021/ac800568y. Epub 2008 Jul 17. Anal Chem. 2008. PMID: 18630928
-
Comparison of primary monoatomic with primary polyatomic ions for the characterisation of polyesters with static secondary ion mass spectrometry.Rapid Commun Mass Spectrom. 2005;19(4):552-60. doi: 10.1002/rcm.1824. Rapid Commun Mass Spectrom. 2005. PMID: 15666315
-
Developments in molecular SIMS depth profiling and 3D imaging of biological systems using polyatomic primary ions.Mass Spectrom Rev. 2011 Jan-Feb;30(1):142-74. doi: 10.1002/mas.20275. Mass Spectrom Rev. 2011. PMID: 20077559 Review.
-
Cluster secondary ion mass spectrometry of polymers and related materials.Mass Spectrom Rev. 2010 Mar-Apr;29(2):247-93. doi: 10.1002/mas.20233. Mass Spectrom Rev. 2010. PMID: 19449334 Review.
Cited by
-
TOF-SIMS imaging of adsorbed proteins on topographically complex surfaces with Bi(3) (+) primary ions.Biointerphases. 2011 Sep;6(3):135. doi: 10.1116/1.3622347. Biointerphases. 2011. PMID: 21974684 Free PMC article.