Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound
- PMID: 18403739
- DOI: 10.1161/STROKEAHA.107.503482
Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound
Abstract
Background and purpose: To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow.
Methods: Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collateral flow were compared between DynAngio, transcranial color-coded duplex ultrasound, and time-of-flight MRA.
Results: There was a good agreement between the methods, with sensitivities between 80% and 90%. Small collateral vessels were detected more frequently with DynAngio compared to time-of-flight MRA.
Conclusions: DynAngio provides anatomic and similar to transcranial color-coded duplex ultrasound functional information on collateral flow for the assessment of intracranial hemodynamics.