Quantification of power consumption and oxygen transfer characteristics of a stirred miniature bioreactor for predictive fermentation scale-up
- PMID: 18404769
- DOI: 10.1002/bit.21852
Quantification of power consumption and oxygen transfer characteristics of a stirred miniature bioreactor for predictive fermentation scale-up
Abstract
Miniature parallel bioreactors are becoming increasingly important as tools to facilitate rapid bioprocess design. Once the most promising strain and culture conditions have been identified a suitable scale-up basis needs to be established in order that the cell growth rates and product yields achieved in small scale optimization studies are maintained at larger scales. Recently we have reported on the design of a miniature stirred bioreactor system capable of parallel operation [Gill et al. (2008); Biochem Eng J 39:164-176]. In order to enable the predictive scale-up of miniature bioreactor results the current study describes a more detailed investigation of the bioreactor mixing and oxygen mass transfer characteristics and the creation of predictive engineering correlations useful for scale-up studies. A Power number of 3.5 for the miniature turbine impeller was first established based on experimental ungassed power consumption measurements. The variation of the measured gassed to ungassed power ratio, P(g)/P(ug), was then shown to be adequately predicted by existing correlations proposed by Cui et al. [Cui et al. (1996); Chem Eng Sci 51:2631-2636] and Mockel et al. [Mockel et al. (1990); Acta Biotechnol 10:215-224]. A correlation relating the measured oxygen mass transfer coefficient, k(L)a, to the gassed power per unit volume and superficial gas velocity was also established for the miniature bioreactor. Based on these correlations a series of scale-up studies at matched k(L)a (0.06-0.11 s(-1)) and P(g)/V (657-2,960 W m(-3)) were performed for the batch growth of Escherichia coli TOP10 pQR239 using glycerol as a carbon source. Constant k(L)a was shown to be the most reliable basis for predictive scale-up of miniature bioreactor results to conventional laboratory scale. This gave good agreement in both cell growth and oxygen utilization kinetics over the range of k(L)a values investigated. The work described here thus gives further insight into the performance of the miniature bioreactor design and will aid its use as a tool for rapid fermentation process development.
2008 Wiley Periodicals, Inc.
Similar articles
-
Characterization and application of a miniature 10 mL stirred-tank bioreactor, showing scale-down equivalence with a conventional 7 L reactor.Biotechnol Prog. 2006 May-Jun;22(3):681-8. doi: 10.1021/bp050369y. Biotechnol Prog. 2006. PMID: 16739949
-
Characterization of oxygen transfer in miniature and lab-scale bubble column bioreactors and comparison of microbial growth performance based on constant k(L)a.Biotechnol Prog. 2005 Jul-Aug;21(4):1175-82. doi: 10.1021/bp050064j. Biotechnol Prog. 2005. PMID: 16080699
-
Twenty-four-well plate miniature bioreactor high-throughput system: assessment for microbial cultivations.Biotechnol Bioeng. 2007 Dec 1;98(5):1017-28. doi: 10.1002/bit.21484. Biotechnol Bioeng. 2007. PMID: 17486656
-
Bioreactor scale-up and oxygen transfer rate in microbial processes: an overview.Biotechnol Adv. 2009 Mar-Apr;27(2):153-76. doi: 10.1016/j.biotechadv.2008.10.006. Epub 2008 Nov 12. Biotechnol Adv. 2009. PMID: 19041387 Review.
-
Optimization and scale up of industrial fermentation processes.Appl Microbiol Biotechnol. 2005 Sep;68(4):425-35. doi: 10.1007/s00253-005-0003-0. Epub 2005 Oct 26. Appl Microbiol Biotechnol. 2005. PMID: 16001256 Review.
Cited by
-
Oxygen Uptake Rate Soft-Sensing via Dynamic k L a Computation: Cell Volume and Metabolic Transition Prediction in Mammalian Bioprocesses.Front Bioeng Biotechnol. 2019 Aug 21;7:195. doi: 10.3389/fbioe.2019.00195. eCollection 2019. Front Bioeng Biotechnol. 2019. PMID: 31497597 Free PMC article.
-
Photosynthetic accumulation of carbon storage compounds under CO₂ enrichment by the thermophilic cyanobacterium Thermosynechococcus elongatus.J Ind Microbiol Biotechnol. 2012 Jun;39(6):843-50. doi: 10.1007/s10295-012-1092-2. Epub 2012 Mar 1. J Ind Microbiol Biotechnol. 2012. PMID: 22383176
-
Parallel use of shake flask and microtiter plate online measuring devices (RAMOS and BioLector) reduces the number of experiments in laboratory-scale stirred tank bioreactors.J Biol Eng. 2015 May 30;9:9. doi: 10.1186/s13036-015-0005-0. eCollection 2015. J Biol Eng. 2015. PMID: 26265936 Free PMC article.
-
Breakage of transgenic tobacco roots for monoclonal antibody release in an ultra-scale down shearing device.Biotechnol Bioeng. 2014 Jan;111(1):196-201. doi: 10.1002/bit.25006. Epub 2013 Sep 20. Biotechnol Bioeng. 2014. PMID: 23860965 Free PMC article.
-
Pitfalls in optical on-line monitoring for high-throughput screening of microbial systems.Microb Cell Fact. 2014 Apr 11;13:53. doi: 10.1186/1475-2859-13-53. Microb Cell Fact. 2014. PMID: 24725602 Free PMC article.