Construction of an automated gas chromatography/mass spectrometry system for the analysis of ambient volatile organic compounds with on-line internal standard calibration
- PMID: 18405905
- DOI: 10.1016/j.chroma.2008.03.071
Construction of an automated gas chromatography/mass spectrometry system for the analysis of ambient volatile organic compounds with on-line internal standard calibration
Abstract
An automated sampling and enrichment apparatus coupled with a gas chromatography/mass spectrometry (GC/MS) technique was constructed for the analysis of ambient volatile organic compounds (VOCs). A sorbent trap was built within the system to perform on-line enrichment and thermal desorption of VOCs onto GC/MS. In order to improve analytical precision, calibration accuracy, and to safe-guard the long-term stability of this system, a mechanism to allow on-line internal standard (I.S.) addition to the air sample stream was configured within the sampling and enrichment apparatus. A sub-ppm (v/v) level standard gas mixture containing 1,4-fluorobenzene, chloropentafluorobenzene, 1-bromo-4-fluorobenzene was prepared from their pure forms. A minute amount of this I.S. gas was volumetrically mixed into the sample stream at the time of on-line enrichment of the air sample to compensate for measurement uncertainties. To assess the performance of this VOC GC/MS system, a gas mixture containing numerous VOCs at sub-ppb (v/v) level served as the ambient air sample. Various internal standard methods based on total ion count (TIC) and selective ion monitoring (SIM) modes were attempted to assess the improvement in analytical precision and accuracy. Precision was improved from 7-8% RSD without I.S. to 2-3% with I.S. for the 14 target VOCs. Uncertainties in the calibration curves were also improved with the adoption of I.S. by reducing the relative standard deviation of the slope (Sm%) by an average a factor of 4, and intercept (Sb%) by a factor of 2 for the 14 target VOCs.
Similar articles
-
Quality control in quantification of volatile organic compounds analysed by thermal desorption-gas chromatography-mass spectrometry.J Chromatogr A. 2008 Apr 4;1186(1-2):348-57. doi: 10.1016/j.chroma.2007.11.036. Epub 2007 Nov 19. J Chromatogr A. 2008. PMID: 18062983
-
Ultimate detectability of volatile organic compounds: how much further can we reduce their ambient air sample volumes for analysis?Anal Chem. 2012 Oct 2;84(19):8284-93. doi: 10.1021/ac301792x. Epub 2012 Sep 13. Anal Chem. 2012. PMID: 22934885
-
Non-linear and non-constant variance calibration curves in analysis of volatile organic compounds for testing of water by the purge-and-trap method coupled with gas chromatography/mass spectrometry.Rapid Commun Mass Spectrom. 2004;18(12):1383-91. doi: 10.1002/rcm.1498. Rapid Commun Mass Spectrom. 2004. PMID: 15174195
-
Distribution of volatile organic compounds in Sicilian groundwaters analysed by head space-solid phase micro extraction coupled with gas chromatography mass spectrometry (SPME/GC/MS).Water Res. 2008 Aug;42(14):3563-77. doi: 10.1016/j.watres.2008.07.022. Epub 2008 Jul 24. Water Res. 2008. PMID: 18703213 Review.
-
Gas chromatography coupled to mass spectrometry for analyses of organic compounds and biomarkers as tracers for geological, environmental, and forensic research.J Sep Sci. 2007 Jul;30(10):1516-36. doi: 10.1002/jssc.200600399. J Sep Sci. 2007. PMID: 17623433 Review.
Cited by
-
Harmful gas recognition exploiting a CTL sensor array.Sensors (Basel). 2013 Oct 9;13(10):13509-20. doi: 10.3390/s131013509. Sensors (Basel). 2013. PMID: 24113681 Free PMC article.
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants.Environ Monit Assess. 2016 Jan;188(1):32. doi: 10.1007/s10661-015-5024-2. Epub 2015 Dec 15. Environ Monit Assess. 2016. PMID: 26670041 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous