Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy
- PMID: 18406939
- DOI: 10.1016/j.ijrobp.2007.06.086
Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy
Abstract
The introduction of volumetric X-ray image-guided radiotherapy systems allows improved management of geometric variations in patient setup and internal organ motion. As these systems become a routine clinical modality, we propose a daily quality assurance (QA) program for cone-beam computed tomography (CBCT) integrated with a linear accelerator. The image-guided system used in this work combines a linear accelerator with conventional X-ray tube and an amorphous silicon flat-panel detector mounted orthogonally from the accelerator central beam axis. This article focuses on daily QA protocols germane to geometric accuracy of the CBCT systems and proposes tolerance levels on the basis of more than 3 years of experience with seven CBCT systems used in our clinic. Monthly geometric calibration tests demonstrate the long-term stability of the flex movements, which are reproducible within +/-0.5 mm (95% confidence interval). The daily QA procedure demonstrates that, for rigid phantoms, the accuracy of the image-guided process can be within 1 mm on average, with a 99% confidence interval of +/-2 mm.
Similar articles
-
A quality assurance program for image quality of cone-beam CT guidance in radiation therapy.Med Phys. 2008 May;35(5):1807-15. doi: 10.1118/1.2900110. Med Phys. 2008. PMID: 18561655
-
[Quality control of a kV cone beam computed tomography imaging system].Cancer Radiother. 2009 Sep;13(5):345-52. doi: 10.1016/j.canrad.2009.05.009. Epub 2009 Jul 16. Cancer Radiother. 2009. PMID: 19615928 French.
-
[Investigation on the 3 D geometric accuracy and on the image quality (MTF, SNR and NPS) of volume tomography units (CT, CBCT and DVT)].Rofo. 2012 Jan;184(1):24-31. doi: 10.1055/s-0031-1281818. Epub 2011 Nov 10. Rofo. 2012. PMID: 22076796 German.
-
Quality assurance of image-guidance technologies.Semin Radiat Oncol. 2007 Oct;17(4):278-86. doi: 10.1016/j.semradonc.2007.07.002. Semin Radiat Oncol. 2007. PMID: 17903705 Review.
-
Megavoltage cone-beam CT: system description and clinical applications.Med Dosim. 2006 Spring;31(1):51-61. doi: 10.1016/j.meddos.2005.12.009. Med Dosim. 2006. PMID: 16551529 Review.
Cited by
-
A novel phantom and procedure providing submillimeter accuracy in daily QA tests of accelerators used for stereotactic radiosurgery*.J Appl Clin Med Phys. 2016 Jul 8;17(4):246-253. doi: 10.1120/jacmp.v17i4.6295. J Appl Clin Med Phys. 2016. PMID: 27455506 Free PMC article.
-
Predicting cortical bone strength from DXA and dental cone-beam CT.PLoS One. 2012;7(11):e50008. doi: 10.1371/journal.pone.0050008. Epub 2012 Nov 30. PLoS One. 2012. PMID: 23226234 Free PMC article.
-
Development of image quality assurance measures of the ExacTrac localization system using commercially available image evaluation software and hardware for image-guided radiotherapy.J Appl Clin Med Phys. 2014 Nov 8;15(6):4877. doi: 10.1120/jacmp.v15i6.4877. J Appl Clin Med Phys. 2014. PMID: 25493511 Free PMC article.
-
Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.J Appl Clin Med Phys. 2012 May 10;13(3):3729. doi: 10.1120/jacmp.v13i3.3729. J Appl Clin Med Phys. 2012. PMID: 22584170 Free PMC article.
-
Set-up errors and planning target volume margins in head and neck cancer radiotherapy: a clinical study of image guidance with on-line cone-beam computed tomography.Int J Clin Oncol. 2013 Jun;18(3):418-27. doi: 10.1007/s10147-012-0395-7. Epub 2012 Mar 3. Int J Clin Oncol. 2013. PMID: 22389140
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials