Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve

Affiliations
Comparative Study

Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve

Hiroshi Sugiki et al. J Artif Organs. 2008.

Abstract

Several studies have reported the asynchronous closure of normal bileaflet valves (NBVs), resulting in a split in its closing sound; however, the clinical significance of this split has never been studied in malfunctioning bileaflet valves (MBVs). The study comprised 218 valves in 184 patients, including normal monoleaflet valves (n = 10), NBVs (n = 198), and MBVs (n = 10). Valve function was confirmed by cinefluoroscopy prior to analysis of the valve sound by the Morlet continuous wavelet transform (CWT). The split interval (SI) for each heartbeat was measured, and the coefficient of variation (CV) of its mean (valve SI) was calculated as a parameter for the fluctuation of the SI. The CWT of monoleaflet valves showed a single spike, whereas NBVs exhibited a clear split. There was no significant difference in valve SI between the aortic and mitral positions; however, the mean of the CV was significantly greater in the mitral position (n = 90, 0.507 +/- 0.254) than in aortic position (n = 108, 0.353 +/- 0.228, P = 0.000045). The split was not found in six (aortic; three, mitral; three) of ten patients with MBVs. The other four patients had a distinct split, but the CV was significantly lower for MBVs (0.138 +/- 0.105) than for NBVs (0.343 +/- 0.221, P = 0.042). Receiver-operating characteristics analysis demonstrated the cutoff line of the CV to be 0.112 for detecting malfunctioning aortic valves with the highest accuracy of 86.1%. This new system using the Morlet CWT can detect MBVs. It will be a useful modality for screening the function of bileaflet valves.

PubMed Disclaimer

References

    1. Chest. 1974 Jul;66(1):44-9 - PubMed
    1. J Heart Valve Dis. 2002 Sep;11(5):736-44 - PubMed
    1. J Thorac Cardiovasc Surg. 1989 Jan;97(1):90-4 - PubMed
    1. J Am Coll Cardiol. 1989 Jan;13(1):234-40 - PubMed
    1. J Thorac Cardiovasc Surg. 1981 Feb;81(2):202-11 - PubMed

Publication types

LinkOut - more resources