Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2008 Apr 23;299(16):1903-13.
doi: 10.1001/jama.299.16.1903.

Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial

Collaborators, Affiliations
Randomized Controlled Trial

Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial

Gregg W Stone et al. JAMA. .

Abstract

Context: A thin, cobalt-chromium stent eluting the antiproliferative agent everolimus from a nonadhesive, durable fluoropolymer has shown promise in preliminary studies in improving clinical and angiographic outcomes in patients with coronary artery disease.

Objective: To evaluate the safety and efficacy of an everolimus-eluting stent compared with a widely used paclitaxel-eluting stent.

Design, setting, and patients: The SPIRIT III trial, a prospective, randomized, single-blind, controlled trial enrolling patients at 65 academic and community-based US institutions between June 22, 2005, and March 15, 2006. Patients were 1002 men and women undergoing percutaneous coronary intervention in lesions 28 mm or less in length and with reference vessel diameter between 2.5 and 3.75 mm. Angiographic follow-up was prespecified at 8 months in 564 patients and completed in 436 patients. Clinical follow-up was performed at 1, 6, 9, and 12 months.

Interventions: Patients were randomized 2:1 to receive the everolimus-eluting stent (n = 669) or the paclitaxel-eluting stent (n = 333).

Main outcome measures: The primary end point was noninferiority or superiority of angiographic in-segment late loss. The major secondary end point was noninferiority assessment of target vessel failure events (cardiac death, myocardial infarction, or target vessel revascularization) at 9 months. An additional secondary end point was evaluation of major adverse cardiac events (cardiac death, myocardial infarction, or target lesion revascularization) at 9 and 12 months.

Results: Angiographic in-segment late loss was significantly less in the everolimus-eluting stent group compared with the paclitaxel group (mean, 0.14 [SD, 0.41] mm vs 0.28 [SD, 0.48] mm; difference, -0.14 [95% CI, -0.23 to -0.05]; P < or = .004). The everolimus stent was noninferior to the paclitaxel stent for target vessel failure at 9 months (7.2% vs 9.0%, respectively; difference, -1.9% [95% CI, -5.6% to 1.8%]; relative risk, 0.79 [95% CI, 0.51 to 1.23]; P < .001). The everolimus stent compared with the paclitaxel stent resulted in significant reductions in composite major adverse cardiac events both at 9 months (4.6% vs 8.1%; relative risk, 0.56 [95% CI, 0.34 to 0.94]; P = .03) and at 1 year (6.0% vs 10.3%; relative risk, 0.58 [95% CI, 0.37 to 0.90]; P = .02), due to fewer myocardial infarctions and target lesion revascularization procedures.

Conclusions: In this large-scale, prospective randomized trial, an everolimus-eluting stent compared with a paclitaxel-eluting stent resulted in reduced angiographic late loss, noninferior rates of target vessel failure, and fewer major adverse cardiac events during 1 year of follow-up.

Trial registration: clinicaltrials.gov Identifier: NCT00180479.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Associated data