Utility of the photoplethysmogram in circulatory monitoring
- PMID: 18431132
- DOI: 10.1097/ALN.0b013e31816c89e1
Utility of the photoplethysmogram in circulatory monitoring
Abstract
The photoplethysmogram is a noninvasive circulatory signal related to the pulsatile volume of blood in tissue and is displayed by many pulse oximeters and bedside monitors, along with the computed arterial oxygen saturation. The photoplethysmogram is similar in appearance to an arterial blood pressure waveform. Because the former is noninvasive and nearly ubiquitous in hospitals whereas the latter requires invasive measurement, the extraction of circulatory information from the photoplethysmogram has been a popular subject of contemporary research. The photoplethysmogram is a function of the underlying circulation, but the relation is complicated by optical, biomechanical, and physiologic covariates that affect the appearance of the photoplethysmogram. Overall, the photoplethysmogram provides a wealth of circulatory information, but its complex etiology may be a limitation in some novel applications.
Similar articles
-
Noninvasive monitoring by photoplethysmography.Clin Perinatol. 2012 Sep;39(3):573-83. doi: 10.1016/j.clp.2012.06.012. Clin Perinatol. 2012. PMID: 22954270 Review.
-
Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients.Crit Care. 2005 Oct 5;9(5):R562-8. doi: 10.1186/cc3799. Epub 2005 Aug 23. Crit Care. 2005. PMID: 16277719 Free PMC article.
-
In vivo reflectance of blood and tissue as a function of light wavelength.IEEE Trans Biomed Eng. 1990 Jun;37(6):632-9. doi: 10.1109/10.55667. IEEE Trans Biomed Eng. 1990. PMID: 2354845
-
Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel.Curr Opin Anaesthesiol. 2008 Dec;21(6):779-83. doi: 10.1097/ACO.0b013e328317794d. Curr Opin Anaesthesiol. 2008. PMID: 18997529 Review.
-
Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.J Biomech. 2009 May 29;42(8):1032-7. doi: 10.1016/j.jbiomech.2009.02.011. Epub 2009 Apr 3. J Biomech. 2009. PMID: 19345360
Cited by
-
The importance of sensor contacting force for predicting fluid responsiveness in children using respiratory variations in pulse oximetry plethysmographic waveform.J Clin Monit Comput. 2019 Jun;33(3):393-401. doi: 10.1007/s10877-018-0183-7. Epub 2018 Jul 14. J Clin Monit Comput. 2019. PMID: 30008089
-
Fast pulsatile blood flow measurement in deep tissue through a multimode detection fiber.J Biomed Opt. 2020 May;25(5):1-10. doi: 10.1117/1.JBO.25.5.055003. J Biomed Opt. 2020. PMID: 32406214 Free PMC article.
-
Measurement of area difference ratio of Photoplethysmographic pulse wave in patients with pre-eclampsia.BMC Pregnancy Childbirth. 2018 Jul 3;18(1):280. doi: 10.1186/s12884-018-1914-y. BMC Pregnancy Childbirth. 2018. PMID: 29970018 Free PMC article.
-
Low-frequency component of photoplethysmogram reflects the autonomic control of blood pressure.Biophys J. 2021 Jul 6;120(13):2657-2664. doi: 10.1016/j.bpj.2021.05.020. Epub 2021 Jun 2. Biophys J. 2021. PMID: 34087217 Free PMC article.
-
On the analysis of fingertip photoplethysmogram signals.Curr Cardiol Rev. 2012 Feb;8(1):14-25. doi: 10.2174/157340312801215782. Curr Cardiol Rev. 2012. PMID: 22845812 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources