Ultrasound biomicroscopy in opaque grafts with post-penetrating keratoplasty glaucoma
- PMID: 18434841
- DOI: 10.1097/ICO.0b013e31816373c5
Ultrasound biomicroscopy in opaque grafts with post-penetrating keratoplasty glaucoma
Abstract
Purpose: To evaluate the anterior segment in opaque grafts with post-penetrating keratoplasty glaucoma (PPKG) by using ultrasound biomicroscopy (UBM).
Methods: An observational clinical case series of patients with opaque corneal grafts with PPKG who underwent UBM examination of the anterior chamber is reported. Indication for keratoplasty, lens status, intraocular pressure at the time of presentation, and the time of diagnosis of glaucoma were noted. Examination included slit-lamp biomicroscopy, posterior-segment ultrasound evaluation, and UBM evaluation of the anterior segment.
Results: Thirty-one eyes of 31 patients with PPKG were recruited into the study. The mean intraocular pressure was 35.5 +/- 5.8 mm Hg (range, 26-52 mm Hg). The mean time of follow-up after penetrating keratoplasty was 6.97 +/- 2.98 months (range, 2-16 months). Of the 31 patients, 11 had undergone penetrating keratoplasty for therapeutic purposes (infectious keratitis), whereas the remaining 20 had undergone keratoplasty for optical reasons. Fourteen (45.1%) patients were pseudophakic, 13 (41.9%) were aphakic, and 4 (12.9%) were phakic. The types of synechiae noted on the UBM included peripheral anterior synechiae in 30/31 (96.7%) eyes, synechiae at the graft-host junction in 13/31 (41.93%) eyes, both peripheral anterior synechiae and graft-host junction synechiae in 12/31 (38.7%) eyes, central iridocorneal synechiae in 6/31 (19.3%) eyes, and intraocular lens iris synechiae in 3/31 (9.6%) eyes.
Conclusions: Secondary angle closure caused by anterior synechiae formation is one of the important causes of PPKG in eyes with opaque grafts. UBM serves as a useful tool for anterior-segment evaluation in such cases and can help in planning the site for glaucoma filtering surgeries and drainage devices.
Similar articles
-
Optical coherence tomography of the anterior segment in secondary glaucoma with corneal opacity after penetrating keratoplasty.Br J Ophthalmol. 2007 Feb;91(2):189-92. doi: 10.1136/bjo.2006.100099. Epub 2006 Sep 14. Br J Ophthalmol. 2007. PMID: 16973665 Free PMC article.
-
High-resolution ultrasound biomicroscopy of the anterior segment in patients with dense corneal scars.Ophthalmic Surg. 1994 May;25(5):284-7. Ophthalmic Surg. 1994. PMID: 8058258
-
Use of ultrasound biomicroscopic evaluation in preoperative planning of penetrating keratoplasty.Cornea. 2000 Jan;19(1):17-21. doi: 10.1097/00003226-200001000-00004. Cornea. 2000. PMID: 10632002
-
Ultrasound biomicroscopy in glaucoma.Surv Ophthalmol. 2011 Sep-Oct;56(5):433-50. doi: 10.1016/j.survophthal.2011.04.004. Epub 2011 Jul 23. Surv Ophthalmol. 2011. PMID: 21783220 Review.
-
Graft failure: III. Glaucoma escalation after penetrating keratoplasty.Int Ophthalmol. 2008 Jun;28(3):191-207. doi: 10.1007/s10792-008-9223-5. Int Ophthalmol. 2008. PMID: 18431550 Review.
Cited by
-
Ultrasound Biomicroscopy Measurements of the Normal Thickness for the Ciliary Body and the Iris in a Middle East Population.Clin Ophthalmol. 2022 Jan 10;16:101-109. doi: 10.2147/OPTH.S297977. eCollection 2022. Clin Ophthalmol. 2022. PMID: 35046635 Free PMC article.
-
Post-penetrating keratoplasty glaucoma.Indian J Ophthalmol. 2008 Jul-Aug;56(4):269-77. doi: 10.4103/0301-4738.41410. Indian J Ophthalmol. 2008. PMID: 18579984 Free PMC article. Review.
-
Anterior Ocular Biometrics as Measured by Ultrasound Biomicroscopy.Healthcare (Basel). 2022 Jun 24;10(7):1188. doi: 10.3390/healthcare10071188. Healthcare (Basel). 2022. PMID: 35885715 Free PMC article.
-
Anterior-segment imaging for assessment of glaucoma.Expert Rev Ophthalmol. 2010 Feb 1;5(1):59-74. doi: 10.1586/eop.09.61. Expert Rev Ophthalmol. 2010. PMID: 20305726 Free PMC article.
-
Anterior segment optical coherence tomography for the quantitative evaluation of the anterior segment following Boston keratoprosthesis.PLoS One. 2013 Aug 5;8(8):e70673. doi: 10.1371/journal.pone.0070673. Print 2013. PLoS One. 2013. PMID: 23940621 Free PMC article.