Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 May-Jun;23(3):216-20.
doi: 10.1111/j.1540-8191.2008.00597.x.

Reoperation for aortic false aneurysms: our experience and strategy for safe resternotomy

Affiliations

Reoperation for aortic false aneurysms: our experience and strategy for safe resternotomy

Fabrizio Settepani et al. J Card Surg. 2008 May-Jun.

Abstract

Background and aim of the study: To review our experience with reoperation for aortic false aneurysms (FA) and to present an analysis of the relevant surgical approaches and risks.

Methods: From May 1999 to June 2006, 11 patients underwent a total of 13 reoperations due to aortic false aneurysms, with an incidence of 3% of all thoracic aortic cases. Cardiopulmonary bypass (CPB) and cooling were started before sternotomy in all cases. Three different strategies were adopted for patients depending on the position of the FA in the mediastinum as indicated by a preoperative CT scan. These included: deep hypothermic circulatory arrest (18 degrees C), moderate hypothermia (28 degrees C), and mild hypothermia (32 degrees C). In two patients, the sternotomy ruptured the FA causing profuse hemorrhaging. In all the other cases sternotomy was performed without complication. The repair consisted in simple repair by direct suture (10 cases) or extensive repair by refashioning the anastomosis (three cases).

Results: Two hospital deaths occurred with a hospital mortality rate of 16.7%. Permanent neurological deficit developed in one patient. Transient neurological deficit in the form of left lower limb weakness was observed in one patient. False aneurysm recurrence developed in two cases. Among patients present at follow-up (nine survivors), four are in NYHA class I and five in class II.

Conclusions: Aortic false aneurysms carry a high mortality and morbidity rate. Nevertheless, we believe that selecting the right strategy according to the position of the FA in the chest can reduce surgical risk, thus permitting relatively safe resternotomy.

PubMed Disclaimer

LinkOut - more resources