Automatic localization and labeling of EEG sensors (ALLES) in MRI volume
- PMID: 18440243
- DOI: 10.1016/j.neuroimage.2008.02.039
Automatic localization and labeling of EEG sensors (ALLES) in MRI volume
Abstract
Spatial localization of scalp EEG electrodes is a major step for dipole source localization and must be accurate, reproducible and practical. Several methods have been proposed in the last 15 years. The most widely used method is currently electromagnetic digitization. Nevertheless, this method is difficult to use in a clinical environment and has not been validated with a high number of electrodes. In this paper, we introduce a new automatic method for localizing and labeling EEG sensors using MRI. First, we design a new scalp EEG sensor. Secondly, we validate this new technique on a head phantom and then in a clinical environment with volunteers and patients. For this, we compare the reproducibility, accuracy and performance of our method with electromagnetic digitization. We demonstrate that our method provides better reproducibility with a significant difference (p<0.01). Concerning precision, both methods are equally accurate with no statistical differences. To conclude, our method offers the possibility of using MRI volume for both source localization and spatial localization of EEG sensors. Automation makes this method very reproducible and easy to handle in a routine clinical environment.
Similar articles
-
Spatial localization of EEG electrodes.Neurophysiol Clin. 2007 Apr-May;37(2):97-102. doi: 10.1016/j.neucli.2007.03.002. Epub 2007 Apr 3. Neurophysiol Clin. 2007. PMID: 17540292 Review.
-
Dipole estimation errors due to differences in modeling anisotropic conductivities in realistic head models for EEG source analysis.Phys Med Biol. 2008 Apr 7;53(7):1877-94. doi: 10.1088/0031-9155/53/7/005. Epub 2008 Mar 10. Phys Med Biol. 2008. PMID: 18364544
-
Geodesic photogrammetry for localizing sensor positions in dense-array EEG.Clin Neurophysiol. 2005 May;116(5):1130-40. doi: 10.1016/j.clinph.2004.12.022. Clin Neurophysiol. 2005. PMID: 15826854
-
EEG source imaging.Clin Neurophysiol. 2004 Oct;115(10):2195-222. doi: 10.1016/j.clinph.2004.06.001. Clin Neurophysiol. 2004. PMID: 15351361 Review.
-
Usefulness of a 1.5 T MRI-compatible EEG electrode system for routine use in the intensive care unit of a tertiary care hospital.Epilepsy Res. 2009 Mar;84(1):28-32. doi: 10.1016/j.eplepsyres.2008.12.002. Epilepsy Res. 2009. PMID: 19179047
Cited by
-
EEG oscillations reveal neuroplastic changes in pain processing associated with long-term meditation.Sci Rep. 2025 Mar 27;15(1):10604. doi: 10.1038/s41598-025-94223-7. Sci Rep. 2025. PMID: 40148498 Free PMC article.
-
Photogrammetry-Based Head Digitization for Rapid and Accurate Localization of EEG Electrodes and MEG Fiducial Markers Using a Single Digital SLR Camera.Front Neurosci. 2017 May 16;11:264. doi: 10.3389/fnins.2017.00264. eCollection 2017. Front Neurosci. 2017. PMID: 28559791 Free PMC article.
-
Algorithm to find high density EEG scalp coordinates and analysis of their correspondence to structural and functional regions of the brain.J Neurosci Methods. 2014 May 30;229:84-96. doi: 10.1016/j.jneumeth.2014.04.020. Epub 2014 Apr 24. J Neurosci Methods. 2014. PMID: 24769168 Free PMC article.
-
Semi-Automated and Direct Localization and Labeling of EEG Electrodes Using MR Structural Images for Simultaneous fMRI-EEG.Front Neurosci. 2020 Dec 22;14:558981. doi: 10.3389/fnins.2020.558981. eCollection 2020. Front Neurosci. 2020. PMID: 33414699 Free PMC article.
-
Variability of EEG electrode positions and their underlying brain regions: visualizing gel artifacts from a simultaneous EEG-fMRI dataset.Brain Behav. 2022 Feb;12(2):e2476. doi: 10.1002/brb3.2476. Epub 2022 Jan 18. Brain Behav. 2022. PMID: 35040596 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical