Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study
- PMID: 18441753
- DOI: 10.1243/09544119JEIM290
Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study
Abstract
Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in axial rotation (71 +/- 25 N), followed by extension (27 +/- 35 N) and lateral bending (25 +/- 28 N), and they were most repeatable in axial rotation (coefficient of variation, 5 per cent). The EAS accuracy was about 20 per cent in the direct accuracy assessment and about 30 per cent in the disarticulated accuracy test. The latter was very similar to the Tekscan accuracy in the same test. Virtual facet loads (r.m.s.) were small in axial rotation (12 N) and lateral bending (20 N), but relatively large in flexion (34 N) and extension (35 N). The results suggested that the bilateral EAS model could be used to determine the facet joint contact forces in axial rotation but may result in considerable error in flexion, extension, and lateral bending.
Similar articles
-
Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions.J Biomech Eng. 2011 Jul;133(7):071010. doi: 10.1115/1.4004493. J Biomech Eng. 2011. PMID: 21823749 Free PMC article. Review.
-
The Effects of Orientation of Lumbar Facet Joints on the Facet Joint Contact Forces: An In Vitro Biomechanical Study.Spine (Phila Pa 1976). 2018 Feb 15;43(4):E216-E220. doi: 10.1097/BRS.0000000000002290. Spine (Phila Pa 1976). 2018. PMID: 28759478
-
The effect of dynamic posterior stabilization on facet joint contact forces: an in vitro investigation.Spine (Phila Pa 1976). 2008 Jan 1;33(1):19-26. doi: 10.1097/BRS.0b013e31815e7f76. Spine (Phila Pa 1976). 2008. PMID: 18165744
-
Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine.J Biomech. 2006;39(2):348-53. doi: 10.1016/j.jbiomech.2004.12.011. J Biomech. 2006. PMID: 16321637
-
Experimental measurement of ligament force, facet force, and segment motion in the human lumbar spine.J Biomech. 1993 Apr-May;26(4-5):427-38. doi: 10.1016/0021-9290(93)90006-z. J Biomech. 1993. PMID: 8478347 Review.
Cited by
-
Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions.J Biomech Eng. 2011 Jul;133(7):071010. doi: 10.1115/1.4004493. J Biomech Eng. 2011. PMID: 21823749 Free PMC article. Review.
-
Kinematic evaluation of one- and two-level Maverick lumbar total disc replacement caudal to a long thoracolumbar spinal fusion.Eur Spine J. 2012 Jun;21 Suppl 5(Suppl 5):S599-611. doi: 10.1007/s00586-012-2301-4. Epub 2012 Apr 25. Eur Spine J. 2012. PMID: 22531900 Free PMC article.
-
Measurement of the number of lumbar spinal movements in the sagittal plane in a 24-hour period.Eur Spine J. 2014 Nov;23(11):2375-84. doi: 10.1007/s00586-014-3588-0. Epub 2014 Sep 20. Eur Spine J. 2014. PMID: 25238799
-
Biomechanical evaluation of the Total Facet Arthroplasty System® (TFAS®): loading as compared to a rigid posterior instrumentation system.Eur Spine J. 2012 Aug;21(8):1660-73. doi: 10.1007/s00586-012-2253-8. Epub 2012 Mar 10. Eur Spine J. 2012. PMID: 22407270 Free PMC article.
-
Biomechanical response of lumbar facet joints under follower preload: a finite element study.BMC Musculoskelet Disord. 2016 Mar 15;17:126. doi: 10.1186/s12891-016-0980-4. BMC Musculoskelet Disord. 2016. PMID: 26980002 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources