Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2008 Aug;18(8):1015-21.
doi: 10.1007/s11695-007-9378-6. Epub 2008 Apr 29.

Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient

Affiliations
Review

Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient

Donald P Bernstein. Obes Surg. 2008 Aug.

Erratum in

  • Obes Surg. 2008 Aug;18(8):1022

Abstract

The pressure pulse contour method for measuring stroke volume (SV) and cardiac output (CO) has come of age. Various methods have been proposed, but at this time no single technique has shown clear superiority over the others. This commentary and review discusses the various methods, and particularly the pressure recording analytical method (PRAM). Dissection of the method shows that vascular wall abnormalities, which are not unique to the morbidly obese state, represent one more biophysical perturbation causing inaccuracy in stroke volume and cardiac output determination. As PRAM is an uncalibrated method, its accuracy depends on certain assumptions that may not fully explain the multitude of combinations and permutations that define pulsatile blood flow; specifically, the area under the pressure curve during systole and the morphologic characteristics of the waveform throughout the cardiac cycle. As a result of incomplete theory, referenced specifically to the morbidly obese individual, PRAM does not faithfully mimic established reference standards of flow; it systematically underestimates stroke volume and cardiac output. Field equations, that is, equations that are applicable over the full gamut of hemodynamic conditions and vascular pathology, are analytically derived truisms. They require input variables that satisfy the natural state of affairs. To realize this state of absolute biophysical bliss, these variables should ideally be measured. Unfortunately, because of the constraints of practicality, shortcuts to the absolute truth are obligatorily required. As a result, pressure pulse contour methods have evolved that employ curve analysis and neural networking techniques, providing uncalibrated facsimiles of SV and CO.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Cardiovasc Drugs Ther. 1995 Feb;9(1):73-83 - PubMed
    1. Am J Physiol Heart Circ Physiol. 2001 Sep;281(3):H1148-55 - PubMed
    1. Br J Anaesth. 2007 Sep;99(3):329-36 - PubMed
    1. J Cardiothorac Vasc Anesth. 2007 Feb;21(1):3-7 - PubMed
    1. Crit Care Med. 2006 Apr;34(4):1243-6 - PubMed

LinkOut - more resources