Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Dec 1;72(5):1362-7.
doi: 10.1016/j.ijrobp.2008.03.004. Epub 2008 Apr 28.

Development and validation of a standardized method for contouring the brachial plexus: preliminary dosimetric analysis among patients treated with IMRT for head-and-neck cancer

Affiliations

Development and validation of a standardized method for contouring the brachial plexus: preliminary dosimetric analysis among patients treated with IMRT for head-and-neck cancer

William H Hall et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: Although Radiation Therapy Oncology Group protocols have proposed a limiting dose to the brachial plexus for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, essentially no recommendations exist for the delineation of this structure for treatment planning.

Methods and materials: Using anatomic texts, radiologic data, and magnetic resonance imaging, a standardized method for delineating the brachial plexus on 3-mm axial computed tomography images was devised. A neuroradiologist assisted with identification of the brachial plexus and adjacent structures. This organ at risk was then contoured on 10 consecutive patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Dose-volume histogram curves were generated by applying the proposed brachial plexus contour to the initial treatment plan.

Results: The total dose to the planning target volume ranged from 60 to 70 Gy (median, 70). The mean brachial plexus volume was 33 +/- 4 cm(3) (range, 25.1-39.4). The mean irradiated volumes of the brachial plexus were 50 Gy (17 +/- 3 cm(3)), 60 Gy (6 +/- 3 cm(3)), 66 Gy (2 +/- 1 cm(3)), 70 Gy (0 +/- 1 cm(3)). The maximal dose to the brachial plexus was 69.9 Gy (range, 62.3-76.9) and was >/=60 Gy, >/=66 Gy, and >/=70 Gy in 100%, 70%, and 30% of patients, respectively.

Conclusions: This technique provides a precise and accurate method for delineating the brachial plexus organ at risk on treatment planning computed tomography scans. Our dosimetric analysis suggest that for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, brachial plexus routinely receives doses in excess of historic and Radiation Therapy Oncology Group limits.

PubMed Disclaimer

MeSH terms

LinkOut - more resources