Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine
- PMID: 18448303
- DOI: 10.1016/j.jpba.2008.03.024
Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine
Abstract
A new PVC membrane sensor is described as a potentiometric sensor for amiloride. The sensor having amiloride-sodium tetraphenyl phthalate (ion-pair) as an electroactive material and dibutyl phthalate (DBP) as an anion excluder in PVC matrix in the percentage ratio of 4:66:30 (ion-pair: DBP:PVC) (w/w). The membrane sensor exhibits suitable response to amiloride in a concentration range of 1.0 x 10(-2) to 1.0 x 10(-6)mol L(-1) with a limit of detection of 9.9 x 10(-7)mol L(-1). The slope of the system was -54.3+/-1.0 mV decade(-1) over pH range of 2.0-7.0. Selectivity coefficients for amiloride relative to a numbers of potential interfering substances were investigated. The sensor was highly selective for amiloride over a large number of similar compounds. The sensor showing a fast response time of 6s and was used over a period of 2 months with a good reproducibility. The sensor was successfully applied to determination of amiloride in pharmaceutical samples with satisfactory results.
Similar articles
-
Novel lipoate-selective membrane sensor for the flow injection determination of alpha-lipoic acid in pharmaceutical preparations and urine.Talanta. 2008 Feb 15;74(5):1113-21. doi: 10.1016/j.talanta.2007.08.008. Epub 2007 Aug 17. Talanta. 2008. PMID: 18371758
-
Preparation of a diclofenac potentiometric sensor and its application to pharmaceutical analysis and to drug recovery from biological fluids.J Pharm Biomed Anal. 2005 Apr 29;37(5):943-7. doi: 10.1016/j.jpba.2004.07.051. Epub 2005 Jan 5. J Pharm Biomed Anal. 2005. PMID: 15862671
-
Characteristics of new composite- and classical potentiometric sensors for the determination of pioglitazone in some pharmaceutical formulations.J Pharm Biomed Anal. 2008 Sep 10;48(1):57-61. doi: 10.1016/j.jpba.2008.04.029. Epub 2008 May 7. J Pharm Biomed Anal. 2008. PMID: 18555633
-
Recent advances on potentiometric membrane sensors for pharmaceutical analysis.Comb Chem High Throughput Screen. 2011 May;14(4):284-302. doi: 10.2174/138620711795222437. Comb Chem High Throughput Screen. 2011. PMID: 21375501 Review.
-
The light-addressable potentiometric sensor for multi-ion sensing and imaging.Methods. 2005 Sep;37(1):94-102. doi: 10.1016/j.ymeth.2005.05.020. Epub 2005 Sep 30. Methods. 2005. PMID: 16199169 Review.