An overview on extremity dosimetry in medical applications
- PMID: 18448440
- DOI: 10.1093/rpd/ncn149
An overview on extremity dosimetry in medical applications
Abstract
Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some of these applications, the skin of the fingers is the limiting organ for individual monitoring of external radiation. Therefore, sub-group 1 of WG9 deals with the use of extremity dosemeters in medical radiation fields. The wide variety of radiation field characteristics present in a medical environment together with the difficulties in measuring a local dose that is representative for the maximum skin dose, usually with one single detector, makes it difficult to perform accurate extremity dosimetry. Sub-group 1 worked out a thorough literature review on extremity dosimetry issues in diagnostic and therapeutic nuclear medicine and positron emission tomography, interventional radiology and interventional cardiology and brachytherapy. Some studies showed that the annual dose limits could be exceeded if the required protection measures are not taken, especially in nuclear medicine. The continuous progress in new applications and techniques requires an important effort in radiation protection and training.
Similar articles
-
An overview of the use of extremity dosemeters in some European countries for medical applications.Radiat Prot Dosimetry. 2008;131(1):62-6. doi: 10.1093/rpd/ncn229. Epub 2008 Aug 23. Radiat Prot Dosimetry. 2008. PMID: 18723854
-
Extremity exposure in nuclear medicine: preliminary results of a European study.Radiat Prot Dosimetry. 2011 Mar;144(1-4):515-20. doi: 10.1093/rpd/ncq574. Epub 2011 Jan 12. Radiat Prot Dosimetry. 2011. PMID: 21233097
-
Improvements in extremity dose assessment for ionising radiation medical applications.Radiat Prot Dosimetry. 2007;125(1-4):28-32. doi: 10.1093/rpd/ncl533. Epub 2007 Feb 3. Radiat Prot Dosimetry. 2007. PMID: 17277325
-
Personal dose monitoring in hospitals: global assessment, critical applications and future needs.Radiat Prot Dosimetry. 2007;124(3):250-9. doi: 10.1093/rpd/ncm418. Epub 2007 Oct 23. Radiat Prot Dosimetry. 2007. PMID: 17956933 Review.
-
External dosimetry and personnel monitoring.Health Phys. 2005 Jun;88(6):557-64. Health Phys. 2005. PMID: 15891453 Review.
Cited by
-
An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures.Br J Radiol. 2014 Jun;87(1038):20130746. doi: 10.1259/bjr.20130746. Epub 2014 Mar 6. Br J Radiol. 2014. PMID: 24678856 Free PMC article.
-
Back-table specimen scanning using gantry-free hybrid hSPECT/LiDAR imaging: a feasibility study during PSMA-radioguided surgery.Surg Endosc. 2025 Aug 25. doi: 10.1007/s00464-025-12081-w. Online ahead of print. Surg Endosc. 2025. PMID: 40854999
-
Surgical radioguidance with beta-emitting radionuclides; challenges and possibilities: A position paper by the EANM.Eur J Nucl Med Mol Imaging. 2024 Aug;51(10):2903-2921. doi: 10.1007/s00259-023-06560-2. Epub 2024 Jan 8. Eur J Nucl Med Mol Imaging. 2024. PMID: 38189911 Free PMC article. Review.
-
Exposure of treating physician to radiation during prostate brachytherapy using iodine-125 seeds: dose measurements on both hands with thermoluminescence dosimeters.Strahlenther Onkol. 2009 Oct;185(10):689-95. doi: 10.1007/s00066-009-1990-z. Epub 2009 Oct 6. Strahlenther Onkol. 2009. PMID: 19806335
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical