Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff
- PMID: 18451386
- DOI: 10.2106/JBJS.G.00427
Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff
Abstract
Background: It is generally believed that the supraspinatus is the most commonly involved tendon in rotator cuff tears. Clinically, however, atrophy of the infraspinatus muscle is frequently observed in patients with even small to medium-size rotator cuff tears. This fact cannot be fully explained by our current understanding of the anatomical insertions of the supraspinatus and infraspinatus. The purpose of this study was to reinvestigate the humeral insertions of these tendons.
Methods: The study included 113 shoulders from sixty-four cadavers. The humeral insertion areas of the supraspinatus and infraspinatus were investigated in ninety-seven specimens. In sixteen specimens, all muscular portions of the supraspinatus and infraspinatus were removed, leaving the tendinous portions intact, in order to define the specific characteristics of the tendinous portion of the muscles. Another twenty-six shoulders were used to obtain precise measurements of the footprints of the supraspinatus and infraspinatus.
Results: The supraspinatus had a long tendinous portion in the anterior half of the muscle, which always inserted into the anteriormost area of the highest impression on the greater tuberosity and which inserted into the superiormost area of the lesser tuberosity in 21% of the specimens. The footprint of the supraspinatus was triangular in shape, with an average maximum medial-to-lateral length of 6.9 mm and an average maximum anteroposterior width of 12.6 mm. The infraspinatus had a long tendinous portion in the superior half of the muscle, which curved anteriorly and extended to the anterolateral area of the highest impression of the greater tuberosity. The footprint of the infraspinatus was trapezoidal in shape, with an average maximum medial-to-lateral length of 10.2 mm and an average maximum anteroposterior width of 32.7 mm.
Conclusions: The footprint of the supraspinatus on the greater tuberosity is much smaller than previously believed, and this area of the greater tuberosity is actually occupied by a substantial amount of the infraspinatus.
Comment in
-
Humeral insertion of the supraspinatus and infraspinatus.J Bone Joint Surg Am. 2009 May;91(5):1275-6; author reply 1276. J Bone Joint Surg Am. 2009. PMID: 19411480 No abstract available.
Similar articles
-
Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff. Surgical technique.J Bone Joint Surg Am. 2009 Mar 1;91 Suppl 2 Pt 1:1-7. doi: 10.2106/JBJS.H.01426. J Bone Joint Surg Am. 2009. PMID: 19255195
-
Morphology of the humeral insertion of the supraspinatus and infraspinatus tendons: Application to rotator cuff repair.Clin Anat. 2015 Sep;28(6):767-73. doi: 10.1002/ca.22548. Epub 2015 Apr 23. Clin Anat. 2015. PMID: 25914209
-
The superior capsule of the shoulder joint complements the insertion of the rotator cuff.J Shoulder Elbow Surg. 2012 Jul;21(7):867-72. doi: 10.1016/j.jse.2011.04.034. Epub 2011 Aug 4. J Shoulder Elbow Surg. 2012. PMID: 21816631
-
Effect of anterior supraspinatus tendon partial-thickness tears on infraspinatus tendon strain through a range of joint rotation angles.J Shoulder Elbow Surg. 2010 Jun;19(4):617-23. doi: 10.1016/j.jse.2009.10.003. Epub 2010 Jan 15. J Shoulder Elbow Surg. 2010. PMID: 20080051 Free PMC article. Review.
-
The vascularity of the rotator cuff.Clin Sports Med. 1991 Oct;10(4):807-22. Clin Sports Med. 1991. PMID: 1934098 Review.
Cited by
-
Accuracy of Suture Passage During Arthroscopic Remplissage-What Anatomic Landmarks Can Improve It?: A Cadaveric Study.Orthop J Sports Med. 2016 Aug 22;4(8):2325967116663497. doi: 10.1177/2325967116663497. eCollection 2016 Aug. Orthop J Sports Med. 2016. PMID: 27606326 Free PMC article.
-
Three-dimensional sectional measurement approach for serial volume changes in shoulder muscles after arthroscopic rotator cuff repair.Eur J Radiol Open. 2024 Jun 12;13:100577. doi: 10.1016/j.ejro.2024.100577. eCollection 2024 Dec. Eur J Radiol Open. 2024. PMID: 38974784 Free PMC article.
-
Arthroscopic anatomy of the subdeltoid space.Orthop Rev (Pavia). 2013 Sep 9;5(3):e25. doi: 10.4081/or.2013.e25. Orthop Rev (Pavia). 2013. PMID: 24191185 Free PMC article. Review.
-
Enhanced tendon-to-bone repair through adhesive films.Acta Biomater. 2018 Apr 1;70:165-176. doi: 10.1016/j.actbio.2018.01.032. Epub 2018 Feb 8. Acta Biomater. 2018. PMID: 29427745 Free PMC article.
-
Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears.Korean J Radiol. 2014 Nov-Dec;15(6):771-80. doi: 10.3348/kjr.2014.15.6.771. Epub 2014 Nov 7. Korean J Radiol. 2014. PMID: 25469089 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical