Perceived spatial frequency of sinusoidal gratings
- PMID: 18451736
- DOI: 10.1097/OPX.0b013e31816be9fd
Perceived spatial frequency of sinusoidal gratings
Abstract
Purpose: The "frequency-doubling" effect or illusion, in which the apparent spatial frequency of a grating appears to be doubled, is produced when a low spatial frequency sinusoidal grating is counterphase flickered at a high temporal frequency. This study examines changes in apparent spatial frequency of sinusoids of various spatiotemporal content after equating them for detectability.
Methods: Detection contrast thresholds were determined for various spatiotemporal gratings. The perceived spatial frequency was then evaluated using stimuli that were four and six times detection threshold. Match ratios were determined for each spatiotemporal combination, whereby the periodicity of a stationary sinusoid was matched with that of a counterphase flickered grating. The same matching task was repeated under different matching task instructions for five randomly chosen spatiotemporal combinations.
Results: Match ratios were fractional for many spatiotemporal combinations. Apparent spatial frequency ranged from less than veridical to greater than double depending on observer and spatiotemporal stimulus content. The effect of task instruction on match ratios was very small, yet significant.
Conclusions: The appearance of fractional spatial frequency percepts draws into question the notion that frequency-doubling is solely generated by spatially non-linear Y-type magnocellular ganglion cells.
Similar articles
-
Spatial structure of the frequency doubling illusion.Vision Res. 2007 Jun;47(13):1732-44. doi: 10.1016/j.visres.2007.03.013. Epub 2007 May 3. Vision Res. 2007. PMID: 17481693
-
Frequency-doubling illusion under scotopic illumination and in peripheral vision.Invest Ophthalmol Vis Sci. 2007 Jul;48(7):3413-8. doi: 10.1167/iovs.06-1091. Invest Ophthalmol Vis Sci. 2007. PMID: 17591916
-
Mechanisms isolated by frequency-doubling technology perimetry.Invest Ophthalmol Vis Sci. 2002 Feb;43(2):398-401. Invest Ophthalmol Vis Sci. 2002. PMID: 11818383
-
Critical problems in spatial vision.Crit Rev Biomed Eng. 1984;10(2):125-77. Crit Rev Biomed Eng. 1984. PMID: 6365451 Review.
-
Spatial frequency content of the Cardiff and related acuity tests.Ophthalmic Physiol Opt. 2006 Jan;26(1):5-12. doi: 10.1111/j.1475-1313.2005.00353.x. Ophthalmic Physiol Opt. 2006. PMID: 16390476 Review.
Cited by
-
Screening for Patients with Mild Alzheimer Disease Using Frequency Doubling Technology Perimetry.Neuroophthalmology. 2013 Nov 19;37(6):239-246. doi: 10.3109/01658107.2013.830627. eCollection 2013. Neuroophthalmology. 2013. PMID: 28167993 Free PMC article.
-
Should clinical automated perimetry be considered for routine functional assessment of early/intermediate age-related macular degeneration (AMD)? A systematic review of current literature.Ophthalmic Physiol Opt. 2022 Jan;42(1):161-177. doi: 10.1111/opo.12919. Epub 2021 Nov 29. Ophthalmic Physiol Opt. 2022. PMID: 34843120 Free PMC article.
-
Functional assessment of glaucoma: Uncovering progression.Surv Ophthalmol. 2020 Nov-Dec;65(6):639-661. doi: 10.1016/j.survophthal.2020.04.004. Epub 2020 Apr 26. Surv Ophthalmol. 2020. PMID: 32348798 Free PMC article. Review.
-
Steady-state pattern electroretinogram and frequency doubling technology in anisometropic amblyopia.Clin Ophthalmol. 2016 Oct 19;10:2061-2068. doi: 10.2147/OPTH.S117803. eCollection 2016. Clin Ophthalmol. 2016. PMID: 27799733 Free PMC article.
-
Visual field loss in schizophrenia: evaluation of magnocellular pathway dysfunction in schizophrenic patients and their parents.Clin Ophthalmol. 2013;7:1015-21. doi: 10.2147/OPTH.S43897. Epub 2013 May 29. Clin Ophthalmol. 2013. PMID: 23807827 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources