Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
- PMID: 18452132
- DOI: 10.1002/bio.1024
Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
Abstract
A flow injection (FI) method is reported for the determination of l-cysteine, based on its enhancement on chemiluminescence (CL) emission of luminol oxidized by sodium persulphate in alkaline solution. The calibration graph was linear over the range 1.0 x 10(-9)-5.0 x 10(-7) mol/L (r(2) = 0.9992), with relative standard deviations (RSDs) in the range 1.1-2.3% (n = 4). The limit of detection (3 sigma blank) was 5.0 x 10(-10) mol/L with a sample throughput of 120/h. The method was applied to pharmaceuticals and the results obtained were in reasonable agreement with the amount labelled. The proposed method was also applied to cysteine in synthetic amino acid mixtures. Calibration graphs of N-acetylcysteine and glutathione over the range 1.0-50 x 10(-8) and 0.5-7.5 x 10(-7) mol/L were also established (r(2) = 0.998 and 0.9986) with RSDs in the range 1.0-2.0% (n = 4), and the limits of detection (3 sigma blank) were 5.0 x 10(-9) and 1.0 x 10(-8) mol/L, respectively.
Copyright (c) 2008 John Wiley & Sons, Ltd.
Similar articles
-
Determination of thyroxine in pharmaceuticals using flow injection with luminol chemiluminescence inhibition detection.Luminescence. 2006 May-Jun;21(3):174-8. doi: 10.1002/bio.902. Luminescence. 2006. PMID: 16645953
-
[Determination of Levofloxacin by chemiluminescence method].Guang Pu Xue Yu Guang Pu Fen Xi. 2004 Apr;24(4):399-401. Guang Pu Xue Yu Guang Pu Fen Xi. 2004. PMID: 15766140 Chinese.
-
Flow-injection method for the determination of iodide/iodine using Ru(bpy)(3)(3+)-NADH chemiluminescence detection.Luminescence. 2008 Sep-Oct;23(5):316-20. doi: 10.1002/bio.1037. Luminescence. 2008. PMID: 18500696
-
[Recent progress in flow-injection chemiluminescence for pharmaceutical analysis].Guang Pu Xue Yu Guang Pu Fen Xi. 2006 May;26(5):816-20. Guang Pu Xue Yu Guang Pu Fen Xi. 2006. PMID: 16883844 Review. Chinese.
-
Analytical applications of flow injection with chemiluminescence detection--a review.Luminescence. 2001 Jan-Feb;16(1):1-23. doi: 10.1002/bio.607. Luminescence. 2001. PMID: 11180653 Review.
Cited by
-
Peroxidase-like activity of vanadium tetrasulfide submicrospheres and its application to the colorimetric detection of hydrogen peroxide and L-cysteine.Mikrochim Acta. 2019 Nov 15;186(12):784. doi: 10.1007/s00604-019-3942-3. Mikrochim Acta. 2019. PMID: 31732809
-
Colorimetric detection of glutathione based on its inhibitory effect on the peroxidase-mimicking properties of WS2 nanosheets.Mikrochim Acta. 2019 Mar 26;186(4):257. doi: 10.1007/s00604-019-3365-1. Mikrochim Acta. 2019. PMID: 30915577
-
Highly selective and sensitive electrochemical determination of cysteine based on complexation with gold nanoparticle-modified copper-based metal organic frameworks.Anal Bioanal Chem. 2022 Mar;414(7):2343-2353. doi: 10.1007/s00216-021-03852-0. Epub 2022 Jan 4. Anal Bioanal Chem. 2022. PMID: 34984506
-
A highly sensitive and selective competition assay for the detection of cysteine using mercury-specific DNA, Hg and Sybr Green I.Sensors (Basel). 2011;11(11):10187-96. doi: 10.3390/s111110187. Epub 2011 Oct 26. Sensors (Basel). 2011. PMID: 22346638 Free PMC article.
-
A novel luminol-based chemiluminescence method for the determination of amikacin sulfate in serum by using trivalent copper-periodate complex.J Pharm Anal. 2013 Oct;3(5):360-366. doi: 10.1016/j.jpha.2012.12.011. Epub 2013 Jan 11. J Pharm Anal. 2013. PMID: 29403840 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical