Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy
- PMID: 18455326
- DOI: 10.1016/j.ijrobp.2008.02.047
Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy
Abstract
Purpose: Volumetric modulated arc therapy (VMAT) is a novel form of intensity-modulated radiotherapy (IMRT) optimization that allows the radiation dose to be delivered in a single gantry rotation of up to 360 degrees , using either a constant dose rate (cdr-VMAT) or variable dose rate (vdr-VMAT) during rotation. The goal of this study was to compare VMAT prostate RT plans with three-dimensional conformal RT (3D-CRT) and IMRT plans.
Patients and methods: The 3D-CRT, five-field IMRT, cdr-VMAT, and vdr-VMAT RT plans were created for 10 computed tomography data sets from patients undergoing RT for prostate cancer. The parameters evaluated included the doses to organs at risk, equivalent uniform doses, dose homogeneity and conformality, and monitor units required for delivery of a 2-Gy fraction.
Results: The IMRT and both VMAT techniques resulted in lower doses to normal critical structures than 3D-CRT plans for nearly all dosimetric endpoints analyzed. The lowest doses to organs at risk and most favorable equivalent uniform doses were achieved with vdr-VMAT, which was significantly better than IMRT for the rectal and femoral head dosimetric endpoints (p < 0.05) and significantly better than cdr-VMAT for most bladder and rectal endpoints (p < 0.05). The vdr-VMAT and cdr-VMAT plans required fewer monitor units than did the IMRT plans (relative reduction of 42% and 38%, respectively; p = 0.005) but more than for the 3D-CRT plans (p = 0.005).
Conclusion: The IMRT and VMAT techniques achieved highly conformal treatment plans. The vdr-VMAT technique resulted in more favorable dose distributions than the IMRT or cdr-VMAT techniques, and reduced the monitor units required compared with IMRT.
Comment in
-
Volumetric modulated arc therapy for delivery of prostate radiotherapy: in regard to Palma et al. (Int J Radiat Oncol Biol Phys 2008;70:996-1001).Int J Radiat Oncol Biol Phys. 2009 Mar 15;73(4):1286; author reply 1287. doi: 10.1016/j.ijrobp.2008.12.008. Int J Radiat Oncol Biol Phys. 2009. PMID: 19251105 No abstract available.
Similar articles
-
Dose comparisons for conformal, IMRT and VMAT prostate plans.J Med Imaging Radiat Oncol. 2011 Dec;55(6):611-21. doi: 10.1111/j.1754-9485.2011.02310.x. J Med Imaging Radiat Oncol. 2011. PMID: 22141609 Clinical Trial.
-
Evaluation of geometrical uncertainties on localized prostate radiotherapy of patients with bilateral metallic hip prostheses using 3D-CRT, IMRT and VMAT: A planning study.J Xray Sci Technol. 2020;28(2):243-254. doi: 10.3233/XST-190598. J Xray Sci Technol. 2020. PMID: 31985486
-
Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer.Radiother Oncol. 2009 Nov;93(2):226-33. doi: 10.1016/j.radonc.2009.08.011. Epub 2009 Sep 16. Radiother Oncol. 2009. PMID: 19765846
-
Dosimetric justification for the use of volumetric modulated arc therapy in head and neck cancer-A systematic review of the literature.Laryngoscope Investig Otolaryngol. 2021 Aug 16;6(5):999-1007. doi: 10.1002/lio2.642. eCollection 2021 Oct. Laryngoscope Investig Otolaryngol. 2021. PMID: 34667842 Free PMC article. Review.
-
Current status of intensity-modulated radiation therapy (IMRT).Int J Clin Oncol. 2007 Dec;12(6):408-15. doi: 10.1007/s10147-007-0703-9. Epub 2007 Dec 21. Int J Clin Oncol. 2007. PMID: 18071859 Review.
Cited by
-
Treatment planning of VMAT and step-and-shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom-based quality assurance measurements.J Appl Clin Med Phys. 2020 Jan;21(1):62-68. doi: 10.1002/acm2.12788. Epub 2019 Dec 10. J Appl Clin Med Phys. 2020. PMID: 31821729 Free PMC article.
-
Evaluation of QA software system analysis for the static picket fence test.J Appl Clin Med Phys. 2022 Jul;23(7):e13618. doi: 10.1002/acm2.13618. Epub 2022 May 15. J Appl Clin Med Phys. 2022. PMID: 35570379 Free PMC article.
-
Multicriteria optimization informed VMAT planning.Med Dosim. 2014 Spring;39(1):64-73. doi: 10.1016/j.meddos.2013.10.001. Epub 2013 Dec 19. Med Dosim. 2014. PMID: 24360919 Free PMC article.
-
Evaluation of techniques for slice sensitivity profile measurement and analysis.J Appl Clin Med Phys. 2014 Mar 6;15(2):4042. doi: 10.1120/jacmp.v15i2.4042. J Appl Clin Med Phys. 2014. PMID: 24710429 Free PMC article.
-
Comparison of Radiation-Induced Secondary Malignancy Risk Between Sequential and Simultaneous Integrated Boost for the Treatment of Nasopharyngeal Carcinoma: Intensity-Modulated Radiotherapy versus Volumetric-Modulated Arc Therapy.Cancer Manag Res. 2020 Apr 8;12:2513-2521. doi: 10.2147/CMAR.S244901. eCollection 2020. Cancer Manag Res. 2020. PMID: 32308488 Free PMC article.