The image of motor units architecture in the mechanomyographic signal during the single motor unit contraction: in vivo and simulation study
- PMID: 18455438
- DOI: 10.1016/j.jelekin.2008.03.007
The image of motor units architecture in the mechanomyographic signal during the single motor unit contraction: in vivo and simulation study
Abstract
The mechanomyographic (MMG) signal analysis has been performed during single motor unit (MU) contractions of the rat medial gastrocnemius muscle. The MMG has been recorded as a muscle surface displacement by using a laser distance sensor. The profiles of the MMG signal let to categorize these signals for particular MUs into three classes. Class MMG-P (positive) comprises MUs with the MMG signal similar to the force signal profile, where the distance between the muscle surface and the laser sensor increases with the force increase. The class MMG-N (negative) has also the MMG profile similar to the force profile, however the MMG is inverted in comparison to the force signal and the distance measured by using laser sensor decreases with the force increase. The third class MMG-M (mixed) characterize the MMG which initially increases with the force increases and when the force exceeds some level it starts to decrease towards the negative values. The semi-pennate muscle model has been proposed, enabling estimation of the MMG generated by a single MU depending on its localization. The analysis have shown that in the semi-pennate muscle the localization of the MU and the relative position of the laser distance sensor determine the MMG profile and amplitude. Thus, proposed classification of the MMG recordings is not related to the physiological types of MUs, but only to the MU localization and mentioned sensor position. When the distance sensor is located over the middle of the muscle belly, a part of the muscle fibers have endings near the location of the sensor beam. For the MU MMG of class MMG-N the deflection of the muscle surface proximal to the sensor mainly influences the MMG recording, whereas for the MU MMG class MMG-P, it is mainly the distal muscle surface deformation. For the MU MMG of MMG-M type the effects of deformation within the proximal and distal muscle surfaces overlap. The model has been verified with experimental recordings, and its responses are consistent and adequate in comparison to the experimental data.
Similar articles
-
Experimentally verified model of mechanomyograms recorded during single motor unit contractions.J Electromyogr Kinesiol. 2005 Dec;15(6):617-30. doi: 10.1016/j.jelekin.2005.03.005. J Electromyogr Kinesiol. 2005. PMID: 16055349
-
Electromyographic and mechanomyographic estimation of motor unit activation strategy in voluntary force production.Electromyogr Clin Neurophysiol. 2004 Dec;44(8):489-96. Electromyogr Clin Neurophysiol. 2004. PMID: 15646006 Clinical Trial.
-
Non-invasive characterization of single motor unit electromyographic and mechanomyographic activities in the biceps brachii muscle.J Electromyogr Kinesiol. 2006 Feb;16(1):17-24. doi: 10.1016/j.jelekin.2005.02.005. Epub 2005 Aug 19. J Electromyogr Kinesiol. 2006. PMID: 16112874
-
Does the frequency content of the surface mechanomyographic signal reflect motor unit firing rates? A brief review.J Electromyogr Kinesiol. 2007 Feb;17(1):1-13. doi: 10.1016/j.jelekin.2005.12.002. Epub 2006 Feb 23. J Electromyogr Kinesiol. 2007. PMID: 16497517 Review.
-
Unraveling the neurophysiology of muscle fatigue.J Electromyogr Kinesiol. 2011 Apr;21(2):208-19. doi: 10.1016/j.jelekin.2010.10.006. Epub 2010 Nov 10. J Electromyogr Kinesiol. 2011. PMID: 21071242 Review.
Cited by
-
Evidence towards improved estimation of respiratory muscle effort from diaphragm mechanomyographic signals with cardiac vibration interference using sample entropy with fixed tolerance values.PLoS One. 2014 Feb 19;9(2):e88902. doi: 10.1371/journal.pone.0088902. eCollection 2014. PLoS One. 2014. PMID: 24586436 Free PMC article.
-
Assessment of Skeletal Muscle Contractile Properties by Radial Displacement: The Case for Tensiomyography.Sports Med. 2018 Jul;48(7):1607-1620. doi: 10.1007/s40279-018-0912-6. Sports Med. 2018. PMID: 29605838 Free PMC article.
-
Comparison of displacement and acceleration transducers for the characterization of mechanics of muscle and subcutaneous tissues by system identification of a mechanomyogram.Med Biol Eng Comput. 2013 Feb;51(1-2):165-73. doi: 10.1007/s11517-012-0981-x. Epub 2012 Nov 3. Med Biol Eng Comput. 2013. PMID: 23129101 Clinical Trial.
-
System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.Med Biol Eng Comput. 2013 Dec;51(12):1349-55. doi: 10.1007/s11517-013-1107-9. Epub 2013 Aug 11. Med Biol Eng Comput. 2013. PMID: 23934080
-
The temperature sensitivity of motor units in rat soleus.Sci Rep. 2024 Feb 6;14(1):3070. doi: 10.1038/s41598-024-53208-8. Sci Rep. 2024. PMID: 38321022 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials