Magnetic resonance imaging of entheses. Part 2
- PMID: 18455563
- DOI: 10.1016/j.crad.2007.12.010
Magnetic resonance imaging of entheses. Part 2
Abstract
Entheses are the sites of attachment of a tendon, ligament, or joint capsule to bone. In a previous article new options for visualizing entheses and related structures, including ultrashort echo time (UTE) pulse sequences, and magic angle imaging were described. In this article an approach to image interpretation is described together with normal examples using UTE and other pulse sequences with and without magic angle imaging. Examples of images seen in disease are included. The new options for imaging entheses may provide useful options for biomechanical study and recognition of involvement in disease.
Similar articles
-
Magnetic resonance imaging of entheses. Part 1.Clin Radiol. 2008 Jun;63(6):691-703. doi: 10.1016/j.crad.2007.12.011. Epub 2008 Mar 5. Clin Radiol. 2008. PMID: 18455562 Review.
-
Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences.J Magn Reson Imaging. 2007 Feb;25(2):381-9. doi: 10.1002/jmri.20825. J Magn Reson Imaging. 2007. PMID: 17260402 Review.
-
Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence.Magn Reson Imaging. 2010 Feb;28(2):178-84. doi: 10.1016/j.mri.2009.06.002. Epub 2009 Aug 19. Magn Reson Imaging. 2010. PMID: 19695811
-
Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.Magn Reson Imaging. 2005 Jun;23(5):611-8. doi: 10.1016/j.mri.2005.02.017. Magn Reson Imaging. 2005. PMID: 16051035
-
Magnetic resonance imaging of the knee with ultrashort TE pulse sequences.Magn Reson Imaging. 2004 Oct;22(8):1061-7. doi: 10.1016/j.mri.2004.08.018. Magn Reson Imaging. 2004. PMID: 15527992
Cited by
-
Quantitative parametric MRI of articular cartilage: a review of progress and open challenges.Br J Radiol. 2013 Mar;86(1023):20120163. doi: 10.1259/bjr.20120163. Br J Radiol. 2013. PMID: 23407427 Free PMC article. Review.
-
Assessment of ultrashort echo time (UTE) T2* mapping at 3T for the whole knee: repeatability, the effects of fat suppression, and knee position.Quant Imaging Med Surg. 2023 Dec 1;13(12):7893-7909. doi: 10.21037/qims-23-459. Epub 2023 Nov 22. Quant Imaging Med Surg. 2023. PMID: 38106304 Free PMC article.
-
Magnetic resonance imaging of short T2 relaxation components in the musculoskeletal system.Skeletal Radiol. 2009 Mar;38(3):201-5. doi: 10.1007/s00256-008-0592-7. Skeletal Radiol. 2009. PMID: 18941741 Review. No abstract available.
-
Morphologic characterization of meniscal root ligaments in the human knee with magnetic resonance microscopy at 11.7 and 3 T.Skeletal Radiol. 2014 Oct;43(10):1395-402. doi: 10.1007/s00256-014-1941-3. Epub 2014 Jun 24. Skeletal Radiol. 2014. PMID: 24957332
-
UTE imaging in the musculoskeletal system.J Magn Reson Imaging. 2015 Apr;41(4):870-83. doi: 10.1002/jmri.24713. Epub 2014 Jul 16. J Magn Reson Imaging. 2015. PMID: 25045018 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical