[Computer-assisted surgery in total knee replacement. Preliminary results: report of 60 cases]
- PMID: 18456061
- DOI: 10.1016/j.rco.2007.10.005
[Computer-assisted surgery in total knee replacement. Preliminary results: report of 60 cases]
Abstract
Purpose of the study: Conventional techniques proposed for total knee arthroplasty (TKA), necessarily require an acceptable alignment of the lower limb. Computer-assisted surgery is becoming increasingly popular in order to improve the precision of the component alignment, an essential element for good long-term results. The purpose of this prospective study was to present our preliminary results with computer-assisted implantation of TKA.
Material and methods: This was a prospective study of 55 patients (60 knees) included at random for computer-assisted TKA between April 2004 and September 2005. Mean age was 70.5 years. The preoperative assessment noted genu varum in 56 knees and genu valgum in four knees. Three knees with unilateral degenerative disease presented a post traumatic tibia malunion. The same surgeon performed all of the operations using the same prosthesis and navigation system (P.F.C. Sigma). Lower limb alignment and orientation of the prosthetic implants were assessed with standard pre- and postoperative gonometry. Sagittal alignment was measured on the standard X-rays (lateral and anteroposterior view).
Results: Knee alignment improved from 8.1+/-4.5 degrees varus (10 degrees valgus to 18 degrees varus) preoperatively, to 0.4+/-0.6 degrees varus (1 degrees valgus to 2 degrees varus) postoperatively. In the frontal plane, the mean angle of the femoral component on the anteroposterior (ap) view was 89.7+/-0.7 degrees (88-91 degrees). The mean angle of the tibial component on the ap view was 89.9+/-0.7 degrees (88.5-91 degrees). The femorotibial mechanical axis was within +/-2 degrees for all prostheses. In the sagittal plane, the mean angle of the femoral component on the lateral view was 4.8 degrees (3-6.5 degrees). The mean tibial slope was 2.7 degrees (1-4 degrees) for the prostheses with a fixed tibial plateau and 0.2 degrees (-1 degrees to +1 degrees) for those with a rotating plateau. The mean operative time was 135 min (110-180 min) and was inversely proportional to experience. There was one conversion to conventional surgery due to software dysfunction. There were no complications related to the operative technique.
Discussion: The best outcome, particularly in terms of aseptic loosening, is reported for knees with a valgus or varus angle within 3 degrees . The improved accuracy of computer-assisted implantation has enabled better orientation of the components in the frontal, sagittal and horizontal planes with implantations well within this range.
Similar articles
-
[Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study].Rev Chir Orthop Reparatrice Appar Mot. 2001 Feb 1;87(1):18-28. Rev Chir Orthop Reparatrice Appar Mot. 2001. PMID: 11240534 Clinical Trial. French.
-
[Computer-assisted total-knee arthroplasty. Comparison of two successive systems. Learning curve].Rev Chir Orthop Reparatrice Appar Mot. 2008 May;94(3):252-60. doi: 10.1016/j.rco.2008.01.002. Epub 2008 Mar 21. Rev Chir Orthop Reparatrice Appar Mot. 2008. PMID: 18456060 French.
-
Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.Comput Aided Surg. 2012;17(2):86-95. doi: 10.3109/10929088.2012.654408. Comput Aided Surg. 2012. PMID: 22348661
-
Imageless navigation system does not improve component rotational alignment in total knee arthroplasty.J Surg Res. 2011 Dec;171(2):590-600. doi: 10.1016/j.jss.2010.05.006. Epub 2010 Oct 31. J Surg Res. 2011. PMID: 21176919 Review.
-
The current status of computer-assisted high tibial osteotomy, unicompartmental knee replacement, and revision total knee replacement.Instr Course Lect. 2008;57:721-6. Instr Course Lect. 2008. PMID: 18399619 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous