Technical and theoretical considerations about gradient perfusion culture for epithelia used in tissue engineering, biomaterial testing and pharmaceutical research
- PMID: 18458434
- DOI: 10.1088/1748-6041/2/2/R01
Technical and theoretical considerations about gradient perfusion culture for epithelia used in tissue engineering, biomaterial testing and pharmaceutical research
Abstract
Epithelia act as biological barriers, which are exposed to different environments at the luminal and basal sides. To simulate this situation and to improve functional features an in vitro gradient perfusion culture technique was developed in our laboratory. This innovative technique appears to be simple at first sight, but the performance needs practical and theoretical knowledge. To harvest intact epithelia after a long-term gradient culture period of many days, leakage, edge damage and pressure differences in the system have to be avoided so that the epithelial barrier function is maintained continuously. Unexpectedly, one of the major obstacles are micro-injuries in the epithelia caused by gas bubbles, which arise during transportation of the medium or due to respiration of the cultured tissue. Gas bubbles randomly accumulate either at the luminal or basal fluid flow of the gradient perfusion culture container. This phenomenon results in fluid pressure differences between the luminal and basal perfusion compartments of the gradient container, which in turn leads to damage of the barrier function. Consequently, the content of gas bubbles in the transported culture medium has to be minimized. Thus, our technical concept is the reduction of gas bubbles while keeping the content of oxygen constant. To follow this strategy we developed a new type of screw cap for media bottles specifically designed to allow fluid contact only with tube and not with cap material. Furthermore, a gas expander module separates gas bubbles from the liquid phase during transportation of the medium. Finally, a new type of gradient culture container allows a permanent elimination of transported gas bubbles. Application of this innovative equipment optimizes the parallel transportation of fluid in the luminal and basal compartments of a gradient culture container.
Similar articles
-
Renal epithelia in long term gradient culture for biomaterial testing and tissue engineering.Biomed Mater Eng. 2005;15(1-2):51-63. Biomed Mater Eng. 2005. PMID: 15623930
-
A modular culture system for the generation of multiple specialized tissues.Biomaterials. 2010 Apr;31(11):2945-54. doi: 10.1016/j.biomaterials.2009.12.048. Epub 2010 Jan 22. Biomaterials. 2010. PMID: 20096452
-
Advanced technique for long term culture of epithelia in a continuous luminal-basal medium gradient.Biomaterials. 2002 Feb;23(3):805-15. doi: 10.1016/s0142-9612(01)00186-7. Biomaterials. 2002. PMID: 11771700
-
Microfluidic cell culture systems for drug research.Lab Chip. 2010 Apr 21;10(8):939-56. doi: 10.1039/b921695b. Epub 2010 Jan 21. Lab Chip. 2010. PMID: 20358102 Review.
-
Macro- and microscale fluid flow systems for endothelial cell biology.Lab Chip. 2010 Jan 21;10(2):143-60. doi: 10.1039/b913390a. Epub 2009 Oct 9. Lab Chip. 2010. PMID: 20066241 Review.
Cited by
-
Achievements and challenges in bioartificial kidney development.Fibrogenesis Tissue Repair. 2010 Aug 10;3:14. doi: 10.1186/1755-1536-3-14. Fibrogenesis Tissue Repair. 2010. PMID: 20698955 Free PMC article.
-