Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 May;21(3):181-6.
doi: 10.1097/BSD.0b013e318074d388.

Segmental pedicle screwing for idiopathic scoliosis using computer-assisted surgery

Affiliations
Comparative Study

Segmental pedicle screwing for idiopathic scoliosis using computer-assisted surgery

Yoshihito Sakai et al. J Spinal Disord Tech. 2008 May.

Abstract

Study design: Retrospective clinical study.

Objectives: To evaluate the accuracy of computer-assisted surgery for idiopathic scoliosis.

Summary of background data: Segmental pedicle screw fixation has been proven to enable enhanced correction of scoliotic deformities. However, both neurovascular and visceral structures are at potential risk from screw misplacement due to pedicle drift. No reports exist on the accuracy and benefits of computer-assisted surgery for pedicle screwing in scoliosis surgery.

Methods: A total of 40 consecutive patients with idiopathic scoliosis were evaluated. Postoperative computed tomography was assessed for the accuracy of pedicle screw placement in 20 cases treated without a navigation system and 20 cases with a computed tomography-based navigation system. Correlations between registered levels and pedicle perforation were investigated.

Results: Pedicle violation was observed in 28.0% of the control group and 11.4% of the navigation group, with significant differences. No screw misplacements at the registered levels were seen, and the longer the distance between the registered level and level of screw insertion, the higher the rate of pedicle violation. No intraoperative complications caused by pedicle perforation occurred.

Conclusions: In the navigation group, a tendency to lateral perforation at the concave side and medial perforation at the convex side was noted, like in the control group. Use of the navigation system significantly reduced the screw misplacement rate for rotated vertebrae as compared with the control group. Separate registration is recommended for rotated vertebrae when possible.

PubMed Disclaimer

Publication types