In vitro analysis of anterior and posterior fixation in an experimental unstable burst fracture model
- PMID: 18458594
- DOI: 10.1097/BSD.0b013e31807a2f61
In vitro analysis of anterior and posterior fixation in an experimental unstable burst fracture model
Abstract
Study design: A biomechanical comparison of fixation constructs in an experimental fracture model.
Objective: To determine the relative postoperative stability of anterior graft and plating with that of posterior or combined fixation constructs in an unstable thoracolumbar burst fracture model.
Summary of background data: Several treatment modalities have been proposed for unstable thoracolumbar burst fractures, but the optimal technique is unclear. Previous cadaveric biomechanical studies in unstable burst fracture models have not considered the commonly used posterior (interpedicular) and anterior (plate) constructs.
Methods: Nine human spine segments (T11-L3) were potted in epoxy and scanned using dual energy x-ray absorptiometry and computed tomography. Intact specimens had baseline flexibility testing. Unstable L1 burst fractures as verified by computed tomography were created using an impulse load and posterior surgical osteoligamentous destabilization (ie, transection of the lamina, interspinous ligaments, facet capsules, and ligamentum flavum). Specimens were instrumented posteriorly with pedicle screws and rods and tested to 6 Nm in flexion-extension, lateral bending, and torsion. Corpectomy and strut grafting were then performed, and testing was repeated in varying order with posterior fixation, anterior plating and circumferential fixation. Range of motion (ROM) and neutral zone was calculated for each test and fixation groups were compared using analysis of variance.
Results: All specimens had AO B1.2 (unstable burst) fractures. Mean ROM for posterior-only constructs was significantly less than that of the intact in lateral bending, flexion, and extension (P<0.001). Anterior-only constructs after corpectomy and strut grafting generally resulted in a smaller ROM versus intact in flexion (NS: P=0.1) and lateral bending (P<0.001). In contrast, all anterior-only and posterior constructs had greater ROM than intact in torsion (all at P<0.05). Circumferential fixation resulted in statistically smaller ROM compared with all other constructs (P< or =0.04), and reached that of the intact specimen in torsion. Increased ROM was correlated with greater fracture comminution for posterior-only fixation (P<0.05), and was weakly correlated with lower dual energy x-ray absorptiometry score (R=0.3) for anterior-only fixation.
Conclusions: Circumferential instrumentation provided the most rigid fixation, followed by posterior fixation with anterior strut grafting, posterior fixation alone, and by anterior fixation with strut grafting. These results were dependent on bone quality and the comminution severity of the fracture. These results should aid surgical decision making in addition to other factors in the overall clinical situation.
Similar articles
-
Biomechanical evaluation of short-segment posterior instrumentation with and without crosslinks in a human cadaveric unstable thoracolumbar burst fracture model.Spine (Phila Pa 1976). 2010 Feb 1;35(3):278-85. doi: 10.1097/BRS.0b013e3181bda4e6. Spine (Phila Pa 1976). 2010. PMID: 20075769
-
Interbody device endplate engagement effects on motion segment biomechanics.Spine J. 2009 Jul;9(7):564-73. doi: 10.1016/j.spinee.2009.03.014. Epub 2009 May 20. Spine J. 2009. PMID: 19457722
-
Biomechanical comparison of two-level cervical locking posterior screw/rod and hook/rod techniques.Spine J. 2007 Mar-Apr;7(2):194-204. doi: 10.1016/j.spinee.2006.04.015. Epub 2006 Dec 22. Spine J. 2007. PMID: 17321969
-
Three-column ligamentous extension injury of the thoracic spine: a case report and review of the literature.Spine (Phila Pa 1976). 2007 Dec 1;32(25):E785-8. doi: 10.1097/BRS.0b013e31815b60fd. Spine (Phila Pa 1976). 2007. PMID: 18245995 Review.
-
The biomechanics of long versus short fixation for thoracolumbar spine fractures.Spine (Phila Pa 1976). 2006 May 15;31(11 Suppl):S70-9; discussion S104. doi: 10.1097/01.brs.0000218221.47230.dd. Spine (Phila Pa 1976). 2006. PMID: 16685240 Review.
Cited by
-
[Current surgical treatment concepts for traumatic thoracic and lumbar vertebral fractures in adults with good bone quality].Unfallchirurgie (Heidelb). 2025 Mar;128(3):167-180. doi: 10.1007/s00113-024-01505-2. Epub 2024 Dec 6. Unfallchirurgie (Heidelb). 2025. PMID: 39643776 Review. German.
-
Percutaneous Dorsal Instrumentation of Vertebral Burst Fractures: Value of Additional Percutaneous Intravertebral Reposition-Cadaver Study.Biomed Res Int. 2015;2015:434873. doi: 10.1155/2015/434873. Epub 2015 Jun 2. Biomed Res Int. 2015. PMID: 26137481 Free PMC article.
-
Pedicle screw instrumentation plus augmentation vertebroplasty using calcium sulfate for thoracolumbar burst fractures without neurologic deficits.Orthop Surg. 2011 Feb;3(1):1-6. doi: 10.1111/j.1757-7861.2010.00114.x. Orthop Surg. 2011. PMID: 22009973 Free PMC article.
-
Cement Augmented Anterior Reconstruction and Decompression without Posterior Instrumentation: A Less Invasive Surgical Option for Osteoporotic Thoracolumbar Fracture with Cord Compression.Korean J Neurotrauma. 2020 Oct 21;16(2):190-199. doi: 10.13004/kjnt.2020.16.e37. eCollection 2020 Oct. Korean J Neurotrauma. 2020. PMID: 33163427 Free PMC article.
-
The options of the three different surgical approaches for the treatment of Denis type A and B thoracolumbar burst fracture.Eur J Orthop Surg Traumatol. 2014 Jan;24(1):29-35. doi: 10.1007/s00590-012-1152-3. Epub 2012 Dec 23. Eur J Orthop Surg Traumatol. 2014. PMID: 23412275
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous