Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008;16(3):367-82.
doi: 10.1007/s10577-008-1238-2.

High-precision structural analysis of subnuclear complexes in fixed and live cells via spatially modulated illumination (SMI) microscopy

Affiliations

High-precision structural analysis of subnuclear complexes in fixed and live cells via spatially modulated illumination (SMI) microscopy

Jürgen Reymann et al. Chromosome Res. 2008.

Abstract

Spatially modulated illumination (SMI) microscopy is a method of wide field fluorescence microscopy featuring interferometric illumination, which delivers structural information about nanoscale architecture in fluorescently labelled cells. The first prototype of the SMI microscope proved its applicability to a wide range of biological questions. For the SMI live cell imaging this system was enhanced in terms of the development of a completely new upright configuration. This so called Vertico-SMI transfers the advantages of SMI nanoscaling to vital biological systems, and is shown to work consistently at different temperatures using both oil- and water-immersion objective lenses. Furthermore, we increased the speed of data acquisition to minimize errors in the detection signal resulting from cellular or object movement. By performing accurate characterization, the present Vertico-SMI now offers a fully-fledged microscope enabling a complete three-dimensional (3D) SMI data stack to be acquired in less than 2 seconds. We have performed live cell measurements of a tet-operator repeat insert in U2OS cells, which provided the first in vivo signatures of subnuclear complexes. Furthermore, we have successfully implemented an optional optical configuration allowing the generation of high-resolution localization microscopy images of a nuclear pore complex distribution.

PubMed Disclaimer

References

    1. J Am Chem Soc. 2004 Jun 2;126(21):6514-5 - PubMed
    1. Science. 2008 Feb 8;319(5864):810-3 - PubMed
    1. Phys Rev Lett. 2002 Apr 22;88(16):163901 - PubMed
    1. Appl Opt. 2002 Nov 1;41(31):6651-9 - PubMed
    1. Biophys J. 2005 Jun;88(6):4312-8 - PubMed

Publication types

MeSH terms

LinkOut - more resources