Abstract
This study compared the ability of an efficient household liquid crystal display (LCD) and a medical high-resolution LCD to detect small hepatic lesions on unenhanced computed tomography (CT) images. We obtained the images from 100 subjects who had undergone abdominal CT. They consisted of 41 patients with a single space-occupying lesion (SOL) in the liver and 59 control subjects with no SOL. Independently, five radiologists rated their confidence concerning the presence of hepatic SOLs on a continuous scale from 0 to 1. Receiver-operating characteristic (ROC) analysis was performed using the jackknife method using the program LABMRMC. We evaluated the differences in A(z) based on the 95% confidence intervals. The mean A(z) of the five observers was 0.9594 with the efficient household LCD vs. 0.9335 with the medical high-resolution LCD. The difference was -0.0422, and the 95% confidence interval was -0.1101 to 0.0257 (p=0.2203). There was no significant difference in the A(z) value between the two types of LCDs. The diagnostic performance with the household LCD was comparable to that with the high-resolution LCD, implying that the former type of LCD can be used to diagnose CT images.
Similar articles
-
[Diagnostic detection performance of a simulated nodule in chest computed tomography images and gray and color nuclear medicine images: comparison between a medical liquid crystal display monitor and an ordinary liquid crystal display monitor].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014 Aug;70(8):757-67. doi: 10.6009/jjrt.2014_jsrt_70.8.757. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014. PMID: 25142386 Japanese.
-
Is targeted reconstruction necessary for evaluating contrast-enhanced chest computed tomography using a liquid crystal display monitor?Radiat Med. 2008 Oct;26(8):474-80. doi: 10.1007/s11604-008-0260-9. Epub 2008 Oct 31. Radiat Med. 2008. PMID: 18975048
-
Comparison of liquid crystal display monitors calibrated with gray-scale standard display function and with γ 2.2 and iPad: observer performance in detection of cerebral infarction on brain CT.AJR Am J Roentgenol. 2013 Jun;200(6):1304-9. doi: 10.2214/AJR.12.9096. AJR Am J Roentgenol. 2013. PMID: 23701069
-
Detectability of T1a lung cancer on digital chest radiographs: an observer-performance comparison among 2-megapixel general-purpose, 2-megapixel medical-purpose, and 3-megapixel medical-purpose liquid-crystal display (LCD) monitors.Acta Radiol. 2015 Aug;56(8):943-9. doi: 10.1177/0284185114544244. Epub 2014 Aug 28. Acta Radiol. 2015. PMID: 25168020 Clinical Trial.
-
[Improvement in diagnosis of liver metastases with the multi-detector CT].Radiologe. 2001 Jan;41(1):16-23. doi: 10.1007/s001170050923. Radiologe. 2001. PMID: 11220094 Review. German.
Cited by
-
Technical and radiological image quality comparison of different liquid crystal displays for radiology.Med Devices (Auckl). 2014 Oct 31;7:371-7. doi: 10.2147/MDER.S67443. eCollection 2014. Med Devices (Auckl). 2014. PMID: 25382988 Free PMC article.
-
Comparison of medical-grade and calibrated consumer-grade displays for diagnosis of subtle bone fissures.Eur Radiol. 2017 Dec;27(12):5049-5055. doi: 10.1007/s00330-017-4923-8. Epub 2017 Jun 28. Eur Radiol. 2017. PMID: 28660305 Clinical Trial.
-
Fusion and subtraction post-processing in body MRI.Pediatr Radiol. 2015 Feb;45(2):273-82. doi: 10.1007/s00247-014-3129-3. Epub 2014 Sep 2. Pediatr Radiol. 2015. PMID: 25179564
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical