Detection of microcystin-metal complexes by using cryospray ionization-Fourier transform ion cyclotron resonance mass spectrometry
- PMID: 18468650
- DOI: 10.1016/j.toxicon.2008.03.026
Detection of microcystin-metal complexes by using cryospray ionization-Fourier transform ion cyclotron resonance mass spectrometry
Abstract
Complexes of microcystins (MCs) and metal ions were detected with mass spectrometry. To observe the MCs-metals complexes, CryoSpray ionization ion source was developed and it was equipped on a commercial Fourier transform ion resonance mass spectrometer. Mixtures of two MCs and five metals were applied to Fourier transform ion cyclotron resonance mass spectrometry coupled with CryoSpray. The analyses showed complexes of MC-LR-Fe(II), -Zn, -Cu, -Mg, MC-RR-Fe(II), -Zn, -Cu, and -Mg but MC-LR-Fe(III) and MC-RR-Fe(III) were not observed. Present study suggested that MCs may play roles in metal ion uptake and/or accumulation in the algal cells.
Similar articles
-
Identification of microcystin toxins from a strain of Microcystis aeruginosa by liquid chromatography introduction into a hybrid linear ion trap-Fourier transform ion cyclotron resonance mass spectrometer.Anal Chem. 2006 Jan 15;78(2):501-12. doi: 10.1021/ac051556d. Anal Chem. 2006. PMID: 16408933
-
Speciation of M+3-hydroxypyrone chelation complexes by electrospray ionization ion trap and Fourier transform ion cyclotron resonance mass spectrometry.Rapid Commun Mass Spectrom. 2007;21(16):2594-600. doi: 10.1002/rcm.3131. Rapid Commun Mass Spectrom. 2007. PMID: 17639572
-
A high-resolution scanning microprobe matrix-assisted laser desorption/ionization ion source for imaging analysis on an ion trap/Fourier transform ion cyclotron resonance mass spectrometer.Rapid Commun Mass Spectrom. 2008 Oct;22(20):3275-85. doi: 10.1002/rcm.3733. Rapid Commun Mass Spectrom. 2008. PMID: 18819119
-
Tandem mass spectrometry in quadrupole ion trap and ion cyclotron resonance mass spectrometers.Methods Enzymol. 2005;402:109-48. doi: 10.1016/S0076-6879(05)02004-5. Methods Enzymol. 2005. PMID: 16401508 Review.
-
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.Annu Rev Phys Chem. 1999;50:517-36. doi: 10.1146/annurev.physchem.50.1.517. Annu Rev Phys Chem. 1999. PMID: 10575730 Review.
Cited by
-
Iron uptake by toxic and nontoxic strains of Microcystis aeruginosa.Appl Environ Microbiol. 2011 Oct;77(19):7068-71. doi: 10.1128/AEM.05270-11. Epub 2011 Aug 12. Appl Environ Microbiol. 2011. PMID: 21841028 Free PMC article.
-
Transcriptional analysis of the jamaicamide gene cluster from the marine cyanobacterium Lyngbya majuscula and identification of possible regulatory proteins.BMC Microbiol. 2009 Dec 1;9:247. doi: 10.1186/1471-2180-9-247. BMC Microbiol. 2009. PMID: 19951434 Free PMC article.
-
Detailed study of cyanobacterial microcystins using high performance tandem mass spectrometry.J Am Soc Mass Spectrom. 2014 Jul;25(7):1253-62. doi: 10.1007/s13361-014-0893-0. Epub 2014 Apr 30. J Am Soc Mass Spectrom. 2014. PMID: 24781456
-
The Influence of Micronutrient Trace Metals on Microcystis aeruginosa Growth and Toxin Production.Toxins (Basel). 2022 Nov 21;14(11):812. doi: 10.3390/toxins14110812. Toxins (Basel). 2022. PMID: 36422986 Free PMC article.
-
A Review of the Effect of Trace Metals on Freshwater Cyanobacterial Growth and Toxin Production.Toxins (Basel). 2019 Nov 5;11(11):643. doi: 10.3390/toxins11110643. Toxins (Basel). 2019. PMID: 31694295 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources