Computer-aided evaluation of anatomical accuracy of image fusion between X-ray CT and SPECT
- PMID: 18468862
- DOI: 10.1016/j.compmedimag.2008.03.002
Computer-aided evaluation of anatomical accuracy of image fusion between X-ray CT and SPECT
Abstract
Hybrid scanners, which enable the performance of single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) in one imaging session, have considerable diagnostic potential. However, evaluating the anatomical accuracy of image fusion inherent to these systems remains a challenge. This paper proposes a method for evaluating this variable with minimum user interaction. It focuses on measuring the distance between the centers of gravity of the SPECT hot spot and its counterpart in the CT image. A localized maximally stable extremal regions method is proposed to automatically segment SPECT hot spots, while the corresponding CT structures are segmented by the semi-automatic random walk method, based on a fast multigrid solver. Accuracy and reproducibility of the validation method have been preliminary confirmed by the test with 21 clinical data-sets.
Similar articles
-
A dual modality approach to quantitative quality control in emission tomography.Phys Med Biol. 2005 Aug 7;50(15):N187-94. doi: 10.1088/0031-9155/50/15/N03. Epub 2005 Jul 19. Phys Med Biol. 2005. PMID: 16030376
-
The role of single-photon emission computed tomography/computed tomography in benign and malignant bone disease.Semin Nucl Med. 2006 Oct;36(4):286-94. doi: 10.1053/j.semnuclmed.2006.05.001. Semin Nucl Med. 2006. PMID: 16950146 Review.
-
Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.Semin Nucl Med. 2006 Oct;36(4):275-85. doi: 10.1053/j.semnuclmed.2006.05.003. Semin Nucl Med. 2006. PMID: 16950145 Review.
-
Endocrine neoplasm scintigraphy: added value of fusing SPECT/CT images compared with traditional side-by-side analysis.Clin Nucl Med. 2006 Nov;31(11):665-72. doi: 10.1097/01.rlu.0000242599.22310.d2. Clin Nucl Med. 2006. PMID: 17053381
-
Cardiac image fusion from stand-alone SPECT and CT: clinical experience.J Nucl Med. 2007 May;48(5):696-703. doi: 10.2967/jnumed.106.037606. J Nucl Med. 2007. PMID: 17475956
Cited by
-
Evaluation of diagnosis techniques used for spinal injury related back pain.Pain Res Treat. 2011;2011:478798. doi: 10.1155/2011/478798. Epub 2011 Jun 13. Pain Res Treat. 2011. PMID: 22110925 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical