Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 May 15;101(10):1504-9.
doi: 10.1016/j.amjcard.2008.01.037. Epub 2008 Mar 21.

Usefulness of new diastolic strain and strain rate indexes for the estimation of left ventricular filling pressure

Affiliations
Comparative Study

Usefulness of new diastolic strain and strain rate indexes for the estimation of left ventricular filling pressure

Hisham Dokainish et al. Am J Cardiol. .

Abstract

Tissue Doppler indexes of left ventricular (LV) filling pressure are prone to angulation errors and tethering and are less reliable in patients with preserved LV ejection fraction and indeterminate early peak transmitral diastolic flow (E)/mitral early diastolic velocity (Ea) (8 <E/Ea <15). Two-dimensional echocardiographic global longitudinal diastolic strain (Ds) and strain rate (DSr) were measured during peak mitral filling, and combined with E, derived new noninvasive indexes of LV filling pressure (E/Ds and E/10DSr). These indexes were compared with simultaneously invasively measured LV preatrial (pre-A) contraction pressure and E/Ea. Fifty patients were studied. Mean age was 55.9 +/- 9.9 years, 22 (43%) were women, and mean LV ejection fraction was 49.3 +/- 18.0%. Ds (R = 0.48, p <0.001) and DSr (R = 0.43, p = 0.002) correlated with invasively measured -dP/dt. Correlations between E/Ds and E/10DSr with LV pre-A pressure were R = 0.81 (p <0.001) and R = 0.80 (p <0.001) compared with R = 0.63 (p <0.001) between E/Ea and LV pre-A pressure, respectively. E/Ds > or =8 had higher sensitivity and specificity (95% and 94%, respectively; area under the curve = 0.96, p <0.0001) than E/Ea > or =15 (sensitivity 81%, specificity 75%; area under the curve = 0.85, p <0.0001) for the prediction of LV pre-A pressure > or =15 mm Hg (p = 0.01 for comparison). In patients with LV ejection fraction > or =50% and 8 <E/Ea <15, E/Ds and E/DSr were more accurate than E/Ea for determination of LV pre-A pressure. In conclusion, a novel ratio 2-dimensional echocardiographic diastolic strain ratio (E/Ds) was a better predictor of LV filling pressure than E/Ea. In patients with LV ejection fraction > or =50% or indeterminate E/Ea, both E/Ds and E/10DSr (a ratio based on global DSR) were better predictors of LV filling pressure than E/Ea.

PubMed Disclaimer

Publication types

LinkOut - more resources