Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996;5(5):382-9.
doi: 10.1155/S0962935196000555.

A blinded comparison of fluticasone propionate with budesonide via powder devices in adult patients with moderate-to-severe asthma: a clinical evaluation

Affiliations

A blinded comparison of fluticasone propionate with budesonide via powder devices in adult patients with moderate-to-severe asthma: a clinical evaluation

N Ringdal et al. Mediators Inflamm. 1996.

Abstract

In Vitro and in vivo data have demonstrated that there are detectable differences between inhaled corticosteroids commonly used to treat asthma. However, controversy still remains as to whether these differences translate into clinical benefits. This 12-week, international, randomized, doubleblind, parallel-group study was undertaken to compare the efficacy and safety of fluticasone propionate (FP) 800 mug daily, administered as a powder via the Diskhaler((R)), and budesonide (BUD) 1600 mug daily, administered using the Turbuhaler((R)), in adult patients with moderate-tosevere asthma. A total of 518 patients participated in the study, 256 of whom received FP and 262 BUD. Assessment of mean morning peak expiratory flow (PEF) over the 12-week treatment period revealed a statistically significant difference in efficacy between FP 800 mug daily and BUD 1600 mug daily in favour of FP (p = 0.003), with an overall improvement of 20.9 l/min with FP compared with 12.4 l/min on BUD. Statistically significant differences in favour of FP were seen over the 12 weeks for mean evening PEF (p = 0.04), diurnal PEF variation (p = 0.03) and percentage predicted PEF (p = 0.003), as well as forced expiratory volume (p = 0.008), forced vital capacity (p = 0.02) and PEF (p = 0.005) measured at clinic visits. The median percentage of symptom-free nights increased over the 12-week study period in both treatment groups, with similar changes seen for the median percentage of days with symptom score < 2, rescue medication use and exacerbations of asthma. The incidence of adverse events was found to be comparable in the two treatment groups. The geometric mean ratios of serum cortisol levels were found to be 1.03 for FP, indicating no mean hypothalamic-pituitary-adrenal axis suppression from baseline, and 0.93 for BUD (p = 0.0002 compared with FP). In summary, FP 800 mug daily showed a greater efficacy/safety ratio in the treatment of moderate-to-severe asthma than BUD 1600 mug daily.

PubMed Disclaimer

References

    1. Respir Med. 1993 Nov;87(8):609-20 - PubMed
    1. Respir Med. 1990 Nov;84 Suppl A:25-9 - PubMed
    1. Eur Respir J. 1992 Oct;5(9):1037-9 - PubMed
    1. Respir Med. 1991 Nov;85(6):501-10 - PubMed
    1. Eur Respir J. 1995 Apr;8(4):579-86 - PubMed

LinkOut - more resources