Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel) vs. titanium tacks: a randomised controlled experimental study in pigs
- PMID: 18483783
- DOI: 10.1007/s10029-008-0375-z
Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel) vs. titanium tacks: a randomised controlled experimental study in pigs
Abstract
Background: The main reason for hospital stay after laparoscopic ventral hernia repair (LVHR) is probably pain, which also causes a lengthening of the patient's time to assume normal daily activities and work. It is likely that titanium tacks may be the main contributing factor to early (and maybe chronic) pain after LVHR. Therefore, non-invasive and patient-friendly mesh fixation methods must be considered. The present study was designed to investigate the technical applicability, safety and effect of Tisseel for intraperitoneal mesh fixation.
Methods: Nine 40-kg Danish Landrace female pigs had two pieces of MotifMESH and two pieces of Proceed mesh fixed in the intraperitoneal position by a laparoscopic technique. The two pieces of the same mesh were fixed with fibrin glue (Tisseel) and titanium tacks, respectively. All pigs were euthanised on the 30th postoperative day and the mesh-tissue samples were tested for strength of ingrowth (peel test), adhesion formation, mesh shrinkage and examined for histological alterations.
Results: No meshes were displaced from their initial position at autopsy, but we observed two cases of mesh folding that could have resulted in hernia recurrence in real patients. There were no significant differences in the strength of ingrowth between different mesh types or fixation methods, measured as peel work per area of mesh (J/m2) and peak force per width of mesh (Nmax/cm). The Proceed mesh shrank by 11% compared to 4% for the MotifMESH mesh (p = 0.002). There was no difference in the grade of adhesions (%) between fixation methods (p = 0.794) or different mesh types (p = 0.296). In the same fashion, there was no difference in the strength of adhesions (grades 0-4) between the two fixation methods or different mesh types (p > 0.5, chi2 test). There was no significant difference in the formation of fibrosis or inflammation between the different meshes or fixation methods. All samples showed significant foreign-body reaction with giant cells.
Conclusion: Our results suggest that the laparoscopic fixation of an intraperitoneal mesh with Tisseel is safe and technically feasible in a pig model. There is still no evidence that fibrin-sealing alone is appropriate for intraperitoneal mesh fixation in hernia repair, but the technique might become an alternative or supplement to mechanical mesh fixation. Until then, further experimental research in animal hernia models with larger meshes is needed, especially with a focus on mesh folding and displacement.
Similar articles
-
Pain and convalescence following laparoscopic ventral hernia repair.Dan Med Bull. 2011 Dec;58(12):B4369. Dan Med Bull. 2011. PMID: 22142580 Clinical Trial.
-
Evaluation of intraperitoneal placement of absorbable and nonabsorbable barrier coated mesh secured with fibrin sealant in a New Zealand white rabbit model.Surg Endosc. 2011 Feb;25(2):604-12. doi: 10.1007/s00464-010-1230-8. Epub 2010 Jul 22. Surg Endosc. 2011. PMID: 20652323
-
Fibrin glue for intraperitoneal laparoscopic mesh fixation: a comparative study in a swine model.Surg Endosc. 2011 Mar;25(3):737-48. doi: 10.1007/s00464-010-1244-2. Epub 2010 Jul 31. Surg Endosc. 2011. PMID: 20680350
-
Mesh fixation techniques in primary ventral or incisional hernia repair.Cochrane Database Syst Rev. 2021 May 28;5(5):CD011563. doi: 10.1002/14651858.CD011563.pub2. Cochrane Database Syst Rev. 2021. PMID: 34046884 Free PMC article.
-
Pain and Surgical Outcomes Reporting After Laparoscopic Ventral Hernia Repair in Relation to Mesh Fixation Technique: A Systematic Review and Meta-Analysis of Randomized Clinical Trials.J Laparoendosc Adv Surg Tech A. 2018 Nov;28(11):1298-1315. doi: 10.1089/lap.2017.0609. Epub 2018 Jun 18. J Laparoendosc Adv Surg Tech A. 2018. PMID: 29912610
Cited by
-
Staple Line Coverage with a Polyglycolic Acid Patch and Fibrin Glue without Pleural Abrasion after Thoracoscopic Bullectomy for Primary Spontaneous Pneumothorax.Korean J Thorac Cardiovasc Surg. 2016 Apr;49(2):85-91. doi: 10.5090/kjtcs.2016.49.2.85. Epub 2016 Apr 5. Korean J Thorac Cardiovasc Surg. 2016. PMID: 27066431 Free PMC article.
-
Mesh shrinkage depends on mesh properties and anchoring device: an experimental long-term study in sheep.Hernia. 2017 Feb;21(1):107-113. doi: 10.1007/s10029-016-1528-0. Epub 2016 Aug 11. Hernia. 2017. PMID: 27515807
-
A comparison of a bovine albumin/glutaraldehyde glue versus fibrin sealant for hernia mesh fixation in experimental onlay and IPOM repair in rats.Surg Endosc. 2010 Dec;24(12):3086-94. doi: 10.1007/s00464-010-1094-y. Epub 2010 May 29. Surg Endosc. 2010. PMID: 20512511
-
Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model.Surg Endosc. 2010 Jun;24(6):1501-2; author reply 1503-4. doi: 10.1007/s00464-009-0775-x. Surg Endosc. 2010. PMID: 20033718 No abstract available.
-
Adhesive performance of biomimetic adhesive-coated biologic scaffolds.Biomacromolecules. 2010 Nov 8;11(11):2976-84. doi: 10.1021/bm1007794. Epub 2010 Oct 4. Biomacromolecules. 2010. PMID: 20919699 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical