Clinical Trial
. 2008 May;40(5):370-9.
doi: 10.1055/s-2007-995589.

Effective treatment of early Barrett's neoplasia with stepwise circumferential and focal ablation using the HALO system

Affiliations
Clinical Trial

Effective treatment of early Barrett's neoplasia with stepwise circumferential and focal ablation using the HALO system

J J Gondrie et al. Endoscopy. 2008 May.

Abstract

Study aims: The aim of the current study was to evaluate the efficacy and safety of stepwise circumferential and focal ablation using the HALO system for Barrett's esophagus containing flat, high-grade dysplasia (HGD) or residual dysplasia after endoscopic resection for HGD or intramucosal cancer (IMC).

Methods: Visible abnormalities were removed with endoscopic resection prior to ablation. Persistence of dysplasia and absence of IMC were confirmed with biopsy after endoscopic resection. A balloon-based electrode was used for primary circumferential ablation and an endoscope-mounted electrode was used for secondary focal ablation.

Results: Twelve patients (nine men; median age 70 years) were treated (median Barrett's length 7 cm). Visible abnormalities were removed by endoscopic resection in seven patients. The worst pathological grade of residual Barrett's esophagus after resection and prior to ablation was low-grade dysplasia (LGD) (n = 1) and HGD (n = 11). Patients underwent a median of one circumferential and two focal ablation sessions. Complete remission of dysplasia was achieved in 12/12 patients (100%). Complete endoscopic and histological removal of Barrett's esophagus was achieved in 12/12 patients (100%). There were no ablation-related stenoses, and no subsquamous Barrett's esophagus was observed in 363 biopsies obtained from post-ablation neo-squamous mucosa. Protocolized cleaning of the ablation zone and electrode in between ablations resulted in superior regression of Barrett's esophagus compared with previous studies. During a median follow-up of 14 months no recurrence of dysplasia or Barrett's esophagus was observed.

Conclusions: Stepwise circumferential and focal ablation for Barrett's esophagus with flat HGD or for Barrett's with residual dysplasia after endoscopic resection for HGD/IMC is a safe and effective treatment modality. Its success rate and safety profile compare favorably with alternatives such as esophagectomy, widespread endoscopic resection or photodynamic therapy.

PubMed Disclaimer

Publication types