Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Aug 1;379(1):45-59.
doi: 10.1016/j.ab.2008.04.039. Epub 2008 Apr 27.

A relative and absolute quantification of neutral N-linked oligosaccharides using modification with carboxymethyl trimethylammonium hydrazide and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

Affiliations

A relative and absolute quantification of neutral N-linked oligosaccharides using modification with carboxymethyl trimethylammonium hydrazide and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

Geun-Cheol Gil et al. Anal Biochem. .

Abstract

Quantification of oligosaccharides is of great importance to investigate variations or changes in the glycans of glycoconjugates. Mass spectrometry (MS) has been widely applied to identification and structural analysis of complex oligosaccharides. However, quantification using MS alone is still quite challenging due to heterogeneous charge states and different ionization efficiency of various types of oligosaccharides. To overcome such shortcomings, derivatization with carboxymethyl trimethylammonium hydrazide (Girard's reagent T [GT]) was introduced to generate a permanent cationic charge at the reducing end of neutral oligosaccharides, resulting in mainly [M](+) ion using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), so that the ambiguities caused by metal adduct peaks such as [M+K](+) and [M+Na](+) were avoided. To verify our method, the relative and absolute quantification of neutral glycans from human immunoglobulin G (IgG) and ovalbumin with internal standards of dextran ladders using MALDI-TOF MS were compared with those performed by conventional normal-phase high-performance liquid chromatography (NP-HPLC) profiling. The quantification using GT derivatization and MALDI-TOF MS agreed well with the HPLC profiling data and showed excellent reliability and reproducibility with better resolution and sensitivity. This method was further applied to quantify the enzymatically desialylated N-glycans from miniature pig kidney membrane proteins. The results showed that the low-abundance structures that could not be resolved by NP-HPLC were quantified with high sensitivity. Thus, this novel method of using modification of neutral sugars with GT is quite powerful for neutral glycan analysis, especially to quantify minute glycan samples with undetectable levels using HPLC.