Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2008 May;20(3):180-5.
doi: 10.1016/j.jclinane.2007.07.010.

Intrathecal morphine in anesthesia for cesarean delivery: dose-response relationship for combinations of low-dose intrathecal morphine and spinal bupivacaine

Affiliations
Randomized Controlled Trial

Intrathecal morphine in anesthesia for cesarean delivery: dose-response relationship for combinations of low-dose intrathecal morphine and spinal bupivacaine

Nermin K Girgin et al. J Clin Anesth. 2008 May.

Abstract

Study objective: To evaluate the quality of analgesia and the severity of side effects of intrathecal morphine administered for a dose range of 0.0 to 0.4 mg for postcesarean analgesia with low-dose bupivacaine.

Design: Double-blind, randomized study.

Setting: University hospital.

Patients: 100 ASA physical status I and II term parturients undergoing cesarean delivery with spinal anesthesia in the operating room.

Interventions: Patients were randomized to one of 5 groups to receive 0.0, 0.1, 0.2, 0.3, or 0.4 mg intrathecal morphine in addition to low-dose (7.5 mg) heavy bupivacaine. Each patient received intravenous (IV) patient-controlled analgesia (PCA) with morphine after the operation.

Measurements: 24-hour IV PCA morphine use and visual analog scores for pain were recorded. The severity score (4-point scale) of nausea, vomiting, and pruritus were assessed intraoperatively and at 4-hour intervals during the first 24 hours postoperatively.

Main results: PCA morphine use was higher in the control group (0.0 mg) than in groups receiving 0.1, 0.2, 0.3, or 0.4 mg intrathecal morphine. There was no difference in IV PCA morphine use between the 0.1 and 0.4-mg groups, despite a 4-fold increase in intrathecal morphine dose. There was no difference between groups in nausea and vomiting, but pruritus increased in direct proportion to the dose of intrathecal morphine (linear regression, P = 0.0001).

Conclusions: The dose of 0.1 mg intrathecal morphine produces analgesia comparable with doses as high as 0.4 mg, with significantly less pruritus when combined with low-dose bupivacaine.

PubMed Disclaimer

Publication types

MeSH terms