. 2008;39(1-4):121-32.

Color duplex ultrasound and contrast-enhanced ultrasound in comparison to MS-CT in the detection of endoleak following endovascular aneurysm repair

Affiliations
  • PMID: 18503118

Color duplex ultrasound and contrast-enhanced ultrasound in comparison to MS-CT in the detection of endoleak following endovascular aneurysm repair

D-A Clevert et al. Clin Hemorheol Microcirc. 2008.

Abstract

The purpose of this study was to compare Color Duplex Ultrasound (CDU), Contrast-Enhanced Ultrasound (CEUS) and Multislice Computed Tomography (MS-CT) angiography in the routine follow up of patients following Endovascular Repair (EVAR) of Abdominal Aortic Aneurysm (AAA).43 consecutive patients with AAA underwent endovascular aneurysm repair and were imaged with CDU, CEUS and MS-CT angiography at regular intervals after the procedure. Each imaging modality was evaluated for the detection of endoleaks. The presence of endoleaks was analyzed and the conspicuity of findings was assessed.CTA was used as gold standard in determining the presence of endoleaks. CDU was true positive for endoleaks in 5/43 patients (11.6%) and false positive for endoleaks in 2/43 patients (4.6%). The sensitivity of CDU was therefore 33.3% and its specificity 92.8%; the positive and negative predictive values were 0.71 and 0.72, respectively. CEUS was true positive for the detection of endoleaks in 15/43 patients (34.9%) and false positive in 2/43 patients (4.6%). The sensitivity of CEUS was therefore 100% and its specificity 93%; the positive and negative predictive values were 0.88 and 1. In the follow up the two false positive endoleaks in CEUS were confirmed as true positive endoleaks by CEUS and MS-CT. In our small patient group, contrast-enhanced ultrasound seemed to be more accurately in demonstrating endoleaks after EVAR than MS-CT angiography and may be considered as a primary surveillance modality whereas duplex ultrasound scanning alone is not as sensitive as CEUS and MS-CT angiography in detection of endoleaks. Especially in patients with contraindications for CT contrast agents (e.g. due to renal failure or severe allergy) CEUS provides a good alternative to MS-CT.