Comparative Study
. 2008 Nov;18(11):2535-41.
doi: 10.1007/s00330-008-1051-5. Epub 2008 May 27.

MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging

Affiliations
Comparative Study

MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging

Laurent Huwart et al. Eur Radiol. 2008 Nov.

Abstract

The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 +/- 5.37 for spin-echo versus 21.02 +/- 4.76 for echo-planar, p = 0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r = 0.91 (p < 0.01) with spin-echo and r = 0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p = 0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r = 0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice.

PubMed Disclaimer

References

    1. N Engl J Med. 2001 Feb 15;344(7):495-500 - PubMed
    1. Clin Gastroenterol Hepatol. 2007 Oct;5(10):1207-1213.e2 - PubMed
    1. Hepatology. 2006 Dec;44(6):1511-7 - PubMed
    1. Acta Biomater. 2007 Jan;3(1):127-37 - PubMed
    1. Radiology. 2003 Jun;227(3):617-22 - PubMed

Publication types

Substances

LinkOut - more resources