Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 May 30;9(1):49.
doi: 10.1186/1465-9921-9-49.

The value of ischemia-modified albumin compared with d-dimer in the diagnosis of pulmonary embolism

Affiliations

The value of ischemia-modified albumin compared with d-dimer in the diagnosis of pulmonary embolism

Suleyman Turedi et al. Respir Res. .

Abstract

Study objective: The primary aim of this study was to investigate whether IMA levels are helpful in the diagnosis of pulmonary embolism (PE). The secondary aim was to determine whether IMA was more effective alone or in combination with clinical probability scores in the diagnosis of PE. Thirdly, the sensitivity and specificity of IMA is compared with D-dimer both with and without clinical probability scores in patients with suspected PE.

Methods: Consecutive patients presenting to the emergency department with suspected PE were prospectively recruited, and healthy volunteers were also enrolled as controls. D-dimer and IMA levels were measured for the entire study group. Wells and Geneva scores were calculated and s-CTPA was performed on all suspected PE patients.

Results: The study population consisted of 130 patients with suspected PE and 59 healthy controls. Mean IMA levels were 0.362 +/- 0.11 ABSU for Group A, the PE group (n = 75); 0.265 +/- 0.07 ABSU for Group B, the non-PE group (n = 55); and 0.175 +/- 0.05 ABSU for Group C, the healthy control group (p < 0.0001). At a cut-off point of 0.25 ABSU, IMA was 93% sensitive and 75% specific in the diagnosis of PE. PPV was 79.4% and NPV was 78.6%. Mean D-dimer levels were 12.48 +/- 10.88 microg/ml for Group A; 5.36 +/- 7.80 microg/ml for Group B and 0.36 +/- 0.16 microg/ml for Group C (p < 0.0001). The D-dimer cut-off point was 0.81 microg/ml with a sensitivity of 98.9% and a specificity of 62.7%, PPV of 69.4% and NPV of 83.3%. The use of IMA in combination with Wells and Geneva clinical probability scores was determined to have a positive impact on these scores' sensitivity and negative predictive values.

Conclusion: IMA is a good alternative to D-dimer in PE diagnosis in terms of both cost and efficiency. Used in combination with clinical probability scores, it has a similar positive effect on NPV and sensitivity to that of D-dimer. The PPV of IMA is better than D-dimer, but it is still unable to confirm a diagnosis of PE without additional investigation.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Our diagnostic work-up in suspected PE patients.
Figure 2
Figure 2
Receiver operating characteristics of ischemia modified albumin levels.
Figure 3
Figure 3
Receiver operating characteristics of D-dimer levels.
Figure 4
Figure 4
Scattergram of the serum IMA levels in all groups.
Figure 5
Figure 5
Scattergram of the serum D-dimer levels in all groups.
Figure 6
Figure 6
Receiver operating characteristics (ROC) curve of Wells score.
Figure 7
Figure 7
Receiver operating characteristics (ROC) curve of Geneva score.

Similar articles

Cited by

References

    1. Palla A, Giuntini C. Diagnosis of pulmonary embolism: have we reached our goal? Respiration. 2004;71:22–3. doi: 10.1159/000075644. - DOI - PubMed
    1. Nilsson T, Söderberg M, Lundqvist G, Cederlund K, Larsen F, Rasmussen E, Svane B, Brohult J, Johnsson H. A comparison of spiral computed tomography and latex agglutination D-dimer assay in acute pulmonary embolism using pulmonary arteriography as gold standard. Scand Cardiovasc J. 2002;36:373–7. doi: 10.1080/140174302762659111. - DOI - PubMed
    1. Dusek J, St'ásek J, Tichý M, Bis J, Gregor J, Vojácek J, Masín V, Polanský P, Brtko M, Cernohorský D. Prognostic significance of ischemia modified albumin after percutaneous coronary intervention. Clin Chim Acta. 2006;367:77–80. doi: 10.1016/j.cca.2005.11.020. - DOI - PubMed
    1. Abboud H, Labreuche J, Meseguer E, Lavallee PC, Simon O, Olivot JM, Mazighi M, Dehoux M, Benessiano J, Steg PG, Amarenco P. Ischemia-modified albumin in acute stroke. Cerebrovasc Dis. 2007;23:216–20. doi: 10.1159/000097644. - DOI - PubMed
    1. Lippi G, Montagnana M, Guidi GC. Albumin cobalt binding and ischemia modified albumin generation: an endogenous response to ischemia? Int J Cardiol. 2006;108:410–1. doi: 10.1016/j.ijcard.2005.03.040. - DOI - PubMed

Substances