Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jul 10;26(20):3346-50.
doi: 10.1200/JCO.2007.14.9229. Epub 2008 Jun 2.

Endobronchial ultrasound with transbronchial needle aspiration for restaging the mediastinum in lung cancer

Affiliations

Endobronchial ultrasound with transbronchial needle aspiration for restaging the mediastinum in lung cancer

Felix J F Herth et al. J Clin Oncol. .

Abstract

Purpose: To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC).

Patients and methods: One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings.

Results: Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at thoracotomy. The majority (91%) of these false negative results were due to nodal sampling error rather than detection error. Overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of EBUS-TBNA for mediastinal restaging after induction chemotherapy were 76%, 100%, 100%, 20%, and 77%, respectively.

Conclusion: EBUS-TBNA is a sensitive, specific, accurate, and minimally invasive test for mediastinal restaging of patients with NSCLC. However, because of the low negative predictive value, tumor-negative findings should be confirmed by surgical staging before thoracotomy.

PubMed Disclaimer

Comment in

Publication types

MeSH terms