Lumped parameter thermal model for the study of vascular reactivity in the fingertip
- PMID: 18532861
- DOI: 10.1115/1.2913233
Lumped parameter thermal model for the study of vascular reactivity in the fingertip
Abstract
Vascular reactivity (VR) denotes changes in volumetric blood flow in response to arterial occlusion. Current techniques to study VR rely on monitoring blood flow parameters and serve to predict the risk of future cardiovascular complications. Because tissue temperature is directly impacted by blood flow, a simplified thermal model was developed to study the alterations in fingertip temperature during arterial occlusion and subsequent reperfusion (hyperemia). This work shows that fingertip temperature variation during VR test can be used as a cost-effective alternative to blood perfusion monitoring. The model developed introduces a function to approximate the temporal alterations in blood volume during VR tests. Parametric studies are performed to analyze the effects of blood perfusion alterations, as well as any environmental contribution to fingertip temperature. Experiments were performed on eight healthy volunteers to study the thermal effect of 3 min of arterial occlusion and subsequent reperfusion (hyperemia). Fingertip temperature and heat flux were measured at the occluded and control fingers, and the finger blood perfusion was determined using venous occlusion plethysmography (VOP). The model was able to phenomenologically reproduce the experimental measurements. Significant variability was observed in the starting fingertip temperature and heat flux measurements among subjects. Difficulty in achieving thermal equilibration was observed, which indicates the important effect of initial temperature and thermal trend (i.e., vasoconstriction, vasodilatation, and oscillations).
Similar articles
-
Comparison of two mathematical models for the study of vascular reactivity.Comput Biol Med. 2009 Jul;39(7):579-89. doi: 10.1016/j.compbiomed.2008.12.003. Epub 2009 Mar 31. Comput Biol Med. 2009. PMID: 19338985
-
Use of temperature alterations to characterize vascular reactivity.Clin Physiol Funct Imaging. 2011 Jan;31(1):66-72. doi: 10.1111/j.1475-097X.2010.00981.x. Epub 2010 Sep 30. Clin Physiol Funct Imaging. 2011. PMID: 20880350
-
Sensitivity of digital thermal monitoring parameters to reactive hyperemia.J Biomech Eng. 2010 May;132(5):051005. doi: 10.1115/1.4001137. J Biomech Eng. 2010. PMID: 20459206
-
Recent developments in modeling heat transfer in blood perfused tissues.IEEE Trans Biomed Eng. 1994 Feb;41(2):97-107. doi: 10.1109/10.284920. IEEE Trans Biomed Eng. 1994. PMID: 8026856 Review.
-
A thermo-pharmacokinetic model of tissue temperature oscillations during localized heating.Int J Hyperthermia. 2005 Mar;21(2):107-24. doi: 10.1080/02656730400020769. Int J Hyperthermia. 2005. PMID: 15764354 Review.
Cited by
-
Dual-mode imaging of cutaneous tissue oxygenation and vascular function.J Vis Exp. 2010 Dec 8;(46):2095. doi: 10.3791/2095. J Vis Exp. 2010. PMID: 21178967 Free PMC article.
-
New Indices of Endothelial Function Measured by Digital Thermal Monitoring of Vascular Reactivity: Data from 6084 Patients Registry.Int J Vasc Med. 2016;2016:1348028. doi: 10.1155/2016/1348028. Epub 2016 Oct 18. Int J Vasc Med. 2016. PMID: 27830091 Free PMC article.
-
Digital thermal monitoring (DTM) of vascular reactivity closely correlates with Doppler flow velocity.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:1100-3. doi: 10.1109/IEMBS.2009.5333962. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964497 Free PMC article.
-
High Frequency of Microvascular Dysfunction in US Outpatient Clinics: A Sign of High Residual Risk? Data from 7,105 Patients.Int J Vasc Med. 2022 Jan 6;2022:4224975. doi: 10.1155/2022/4224975. eCollection 2022. Int J Vasc Med. 2022. PMID: 35036009 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources