Comparative Study
. 2008 Oct;23(7):1057-67.
doi: 10.1016/j.arth.2007.09.019. Epub 2008 Mar 14.

In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty

Affiliations
Comparative Study

In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty

Hal E Cates et al. J Arthroplasty. 2008 Oct.

Abstract

The objective of this study was to determine the in vivo kinematics for subjects having either a fixed posterior stabilized (PS) or cruciate retaining (CR) high-flexion total knee arthroplasty (TKA). Three-dimensional kinematics from full extension to maximum flexion were determined for 30 subjects (15 PS, 15 CR) using fluoroscopy. On average, the PS subjects demonstrated 112 degrees of weight-bearing (WB) flexion, -6.4 mm of posterior femoral rollback, and 2.9 degrees of axial rotation. The CR subjects averaged 117 degrees of WB flexion, -4.9 mm of posterior femoral rollback, and 4.8 degrees of axial rotation. Posterior femoral rollback of the lateral condyle occurred for all PS TKAs and in 93% of the CR TKAs. Only 2 subjects in each group experienced greater than 1.0 mm of condylar lift-off. Subjects in both TKA groups demonstrated excellent WB ranges of motion and kinematic patterns similar to the normal knee, but less in magnitude.