. 2008 Apr;80(4):308-15.
doi: 10.2175/106143007x221021.

Safety aspects of handling and using fecal material from urine-diversion toilets--a field investigation

Affiliations

Safety aspects of handling and using fecal material from urine-diversion toilets--a field investigation

L M Austin et al. Water Environ Res. 2008 Apr.

Abstract

The most advantageous approach to pathogen destruction in a urine-diversion toilet vault is to maximize the effects of various environmental factors (i.e., pH, temperature, moisture content, type of bulking agent, and storage time). To quantify these effects, a field experiment was set up, consisting of 6 urine-diversion toilet vaults, each with a different combination of feces and bulking agent (soil, ash, wood shavings, sodium hydroxide, or straw) and ventilation (ventpipe/no ventpipe). The pH of the mixes varied from 6.37 to 10.09. Temperature probes, which were connected to a data logger, were inserted to the heaps, and the logger monitored over a period of nearly 10 months. Mean heap temperatures ranged from 16.8 degrees C in winter to 27.6 degrees C in summer. In addition, samples were taken at intervals from the various heaps in the vaults and also from an open heap exposed to the elements. The samples were subjected to microbiological testing to quantify the pathogen dieoff over time. In the vaults, there was a 3log10 (99.9%) reduction of total coliform between 130 and 250 days, fecal coliform between 100 and 250 days, and fecal streptococci from 125 days and longer. In the open heap, these times varied, from 115 days for both total and fecal coliform, to 140 days for fecal streptococci. Viable Ascaris ova were reduced to zero between 44 and 174 days in the vaults and by 44 days in the open heap. The results of this research showed that ventilation of the vault by means of a ventpipe does not result in any meaningful difference in the vault temperature or the rate of pathogen dieoff. While the type of bulking agent used does not significantly affect the temperature of the heap, it does have an effect on the rate of pathogen dieoff. The ordinary soil mix was seen to give the best results, and this was ascribed to the effect of competing microorganisms in the soil itself. It is concluded that, for safety, vaults of urine-diversion toilets should be sized for a storage period of 9 to 12 months from the last use.